Sensitive Directional Power (Sen); Sensitive Directional Power General Data Objects - GE UR Series Manual

Hide thumbs Also See for UR Series:
Table of Contents

Advertisement

MODEL IMPLEMENTATION CONFORMANCE STATEMENT (MICS)
RgDifPDIF#
LNName:
data attribute
data obj.
RstA
net
net.instCVal
net.instCVal.mag
.f
net.cVal
net.cVal.mag.f
net.units
net.units.SIUnit
net.units
.multiplier
3
net.db
net.zeroDb
BlkRefγ
setSrcRef
setSrcCB

3.5.2.44 Sensitive directional power (Sen)

This element is instantiated in the following products: C60, D60, F60, G30, G60, L90, M60, N60.
Table 3-65: Sensitive directional power general data objects
SenPDOP#
LNName:
data attribute
data obj.
Str
general
dirGeneral
Op
general
Dpo
stVal
TotW
instMag
instMag.f
mag
mag.f
units
units.SIUnit
units.multiplier
db
zeroDb
BlkRefγ
setSrcRef
setSrcCB
3-70
Prot
LDevice inst:
Type
FC UR Name
WYE
CMV
MX
Vector
FLOAT32
RGF# RESTR Igr magnitude, in
primary amps
MX
Vector
FLOAT32
RGF# RESTR Igr magnitude, in
primary amps, with deadband
CF
Unit
ENUMERATED
ENUMERATED
CF RgDifPDIF#.RstA.net.db
INT32U
CF
INT32U
ORG
SP RESTD GND FT# BLOCK for group
ObjectReference
γ
SP
ObjectReference
Prot
LDevice inst:
Type
FC UR Name
ACD
ST DIR POWER # PKP
BOOLEAN
ST
ENUMERATED
ACT
ST DIR POWER # OP
BOOLEAN
SPS
ST DIR POWER # DPO
BOOLEAN
MV
MX
AnalogueValue
FLOAT32
DIRECTIONAL POWER # 3φ
MX
AnalogueValue
FLOAT32
CF
Unit
ENUMERATED
ENUMERATED
CF SenPDOP#.TotW.db
INT32U
CF
INT32U
ORG
SP DIR POWER # BLK for group γ
ObjectReference
SP
ObjectReference
CHAPTER 3: IEC 61850 COMMUNICATION
Restricted Ground Fault # function
UR element:
Description
Restraint currents
5, the code for amps
0, the code for a multiplier of 1
RESTD GND FT# BLOCK for setting group γ
Reference to the data attribute to input
Source GoCB of input if via GOOSE
Sensitive Directional Power element # core functions
UR element:
Description
DIR POWER # PKP operand, which becomes
On when either stage 1 or stage 2 of this
element has picked up
0, the code for unknown. It is unknown as
the element can be connected/configured
to look forward or backward.
DIR POWER # OP operand
DIR POWER # DPO operand, which is the
inverse of DIR POWER OP
DIRECTIONAL POWER # 3-PHASE, in primary
watts
DIRECTIONAL POWER # 3φ, deadbanded
38, the code for primary watts (J/s)
0, the code for a multiplier of 1
3-phase power cut-off level in percent
multiplied by 1000
DIR POWER # BLK setting for setting group γ
Reference to the data attribute to input
Source GoCB of input if via GOOSE
UR SERIES – COMMUNICATIONS GUIDE
R/W/C
R
R
R
R
R
R
R
R
R
R/W/C
R
R
R/C
R/C
R/W/C
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R/W/C
R
R
R/C
R/C

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents