Products
Address Register name
"
920D
"
920E
"
920F
"
9210
"
9211
F35
9212
2
"
9224
"
9236
"
9248

RRTD Inputs (Read/Write Setting) (12 Modules)

G60, M60, T60
9260
"
9261
"
9267
"
9268
"
9269
"
926A
"
926B
"
926C
"
926D
"
926E
"
926F
"
9271
"
9272
"
9273
"
9274
"
9288
"
929C
"
92B0
"
92C4
"
92D8
"
92EC
"
9300
"
9314
"
9328
"
933C

DCmA Outputs (Read/Write Setting) (24 Modules)

All except B90
9360
"
9361
"
9362
"
9364
"
9366
"
936C
"
9372
"
9378
"
937E
2-118
Fault REM1-TAP Z1 Angle
Fault REM1-TAP Length
Fault REM2-TAP Z1 Magnitude
Fault REM2-TAP Z1 Angle
Fault REM2-TAP Length
...Repeated for Fault Report 2
...Repeated for Fault Report 3
...Repeated for Fault Report 4
...Repeated for Fault Report 5
RRTD RTD 1 Function
RRTD RTD 1 ID
RRTD RTD 1 Type
RRTD RTD 1 Application
RRTD RTD 1 Alarm Temp
RRTD RTD 1 Alarm Pickup Delay
RRTD RTD 1 Trip Temp
RRTD RTD 1 Trip Pickup Delay
RRTD RTD 1 Trip Reset Delay
RRTD RTD 1 Trip Voting
RRTD RTD 1 Block
RRTD RTD 1 Open
RRTD RTD 1 Target
RRTD RTD 1 Events
...Repeated for RRTD RTD 2
...Repeated for RRTD RTD 3
...Repeated for RRTD RTD 4
...Repeated for RRTD RTD 5
...Repeated for RRTD RTD 6
...Repeated for RRTD RTD 7
...Repeated for RRTD RTD 8
...Repeated for RRTD RTD 9
...Repeated for RRTD RTD 10
...Repeated for RRTD RTD 11
...Repeated for RRTD RTD 12
DCmA Output 1 Source
DCmA Output 1 Range
DCmA Output 1 Minimum
DCmA Output 1 Maximum
...Repeated for DCmA Output 2
...Repeated for DCmA Output 3
...Repeated for DCmA Output 4
...Repeated for DCmA Output 5
...Repeated for DCmA Output 6
CHAPTER 2: MODBUS COMMUNICATION
Range
Units
Step
25 to 90
degrees 1
0 to 2000
---
0.1
0.01 to 250
ohms
0.01
25 to 90
degrees 1
0 to 2000
---
0.1
0 to 1
---
1
---
---
---
0 to 3
---
1
0 to 5
---
1
1 to 200
°C
1
5 to 600
s
5
1 to 200
°C
1
5 to 600
s
5
5 to 600
s
5
0 to 13
---
1
0 to 4294967295
---
1
0 to 2
---
1
0 to 2
---
1
0 to 1
---
1
---
---
---
---
---
---
---
---
---
---
---
0 to 65535
---
1
0 to 2
---
1
–90 to 90
pu
0.001 F004
–90 to 90
pu
0.001 F004
UR SERIES – COMMUNICATIONS GUIDE
Format
Default
F001
75
F001
1000
F001
300
F001
75
F001
1000
F102
0 (Disabled)
F205
"RRTD 1 "
F174
0 (100 Ohm
Platinum)
F550
0 (None)
F001
130
F001
5
F001
130
F001
5
F001
5
F603
0 (None)
F300
0
F552
0 (None)
F109
0 (Self-reset)
F102
0 (Disabled)
F600
0
F522
0 (–1 to 1
mA)
0
1000

Hide quick links: