Motor Setup (Read/Write Setting); Thermal Model Actual Values (Read Only); Thermal Model Actuals (Read Only); Field Ground Actual Values (Read Only) - GE UR Series Manual

Hide thumbs Also See for UR Series:
Table of Contents

Advertisement

CHAPTER 2: MODBUS COMMUNICATION
Products
Address Register name
"
65D9
Power Swing Detect Quad Reverse Middle
"
65DA
Power Swing Detect Quad Reverse Outer
"
65DB
Power Swing Detect Outer Right Blinder
"
65DC
Power Swing Detect Outer Left Blinder
"
65DD
Power Swing Detect Middle Right Blinder
"
65DE
Power Swing Detect Middle Left Blinder
"
65DF
Power Swing Detect Inner Right Blinder
"
65E0
Power Swing Detect Inner Left Blinder
"
65E1
Power Swing I2 Supervision Enable
"
65E3
Power Swing I2 Supervision
Bus Configuration (Read/Write Setting) (6 Modules)
B90
65EE
Bus Zone x Status (24 items)

Motor Setup (Read/Write Setting)

M60
6600
Thermal Model Motor FLA
"
6601
Thermal Model Motor Overload Factor
"
6602
Thermal Model Line Source
"
6603
Thermal Model Motor Offline
"
6605
Thermal Model RTD 1
"
6606
Thermal Model RTD 2
"
6607
Thermal Model RTD 3
"
6608
Thermal Model RTD 4
"
6609
Thermal Model RTD 5
"
660A
Thermal Model RTD 6
"
660B
Motor Emergency Restart
"
660D
Motor Nameplate Voltage
"
660E
Speed 2 Motor Protection
"
660F
Speed 2 Motor Switch
"
6611
Speed 2 Switch 2-1 Delay
"
6612
Speed 2 Motor Source
"
6613
Speed 2 Motor FLA
Bus Configuration (Read/Write Setting) (6 Modules)
B90
661E
...Repeated for Bus Zone 2

Thermal Model Actual Values (Read Only)

M60
6630
Thermal Model Motor Status
"
6631
Thermal Model Capacity Used
"
6633
Trip Time On Overload
"
6634
Thermal Model Lockout Time

Thermal Model Actuals (Read Only)

M60
6638
Thermal Model Load
"
663A
Thermal Model Motor Unbalance
"
663B
Thermal Model Biased Motor Load
"
663C
Start/Hour Lockout Time
"
663D
Time-Between-Starts Lockout Time
"
663E
Restart Delay Lockout Time
"
663F
Total Motor Lockout Time

Field Ground Actual Values (Read Only)

G60
6640
Field Ground Resistance
UR SERIES – COMMUNICATIONS GUIDE
Range
Units
Step
0.1 to 500
ohms
0.01
0.1 to 500
ohms
0.01
0.1 to 500
ohms
0.01
0.1 to 500
ohms
0.01
0.1 to 500
ohms
0.01
0.1 to 500
ohms
0.01
0.1 to 500
ohms
0.01
0.1 to 500
ohms
0.01
0 to 4294967295
---
1
0.05 to 30
pu
0.001 F001
0 to 4294967295
---
1
0.05 to 1
pu
0.001 F001
1 to 1.5
---
0.01
0 to 5
---
1
0 to 4294967295
---
1
0 to 48
---
1
0 to 48
---
1
0 to 48
---
1
0 to 48
---
1
0 to 48
---
1
0 to 48
---
1
0 to 4294967295
---
1
100 to 50000
V
1
0 to 1
---
1
0 to 4294967295
---
1
0 to 600
s
0.01
0 to 5
---
1
0.05 to 1
pu
0.001 F001
0 to 3
---
1
0 to 100
%
1
0 to 10000
---
1
0 to 65000
min
1
0 to 40
x FLA
0.01
0 to 100
%
1
0 to 40
x FLA
0.01
0 to 65000
min
1
0 to 65000
min
1
0 to 50000
s
1
0 to 65000
min
1
0 to 20000
kOhm
0.001 F003
MEMORY MAP
Format
Default
F001
6000
F001
7000
F001
10000
F001
10000
F001
10000
F001
10000
F001
10000
F001
10000
F300
0
200
F300
0
1000
F001
100
F167
0 (SRC 1)
F300
0
F151
0 (NONE)
F151
0 (NONE)
F151
0 (NONE)
F151
0 (NONE)
F151
0 (NONE)
F151
0 (NONE)
F300
0
F001
600
F102
0 (Disabled)
F300
0
F001
500
F167
0 (SRC 1)
1000
F098
1 (Starting)
F001
0
F001
0
F001
0
F001
0
F001
0
F001
0
F001
0
F001
0
F001
0
F001
0
20000000
2-79
2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents