Direct Inputs/Outputs (Read/Write Setting); Direct Input/Output Commands (Read/Write Command); Direct Inputs (Read/Write Setting) (32, 64, Or 96 Modules) - GE UR Series Manual

Hide thumbs Also See for UR Series:
Table of Contents

Advertisement

MEMORY MAP
Products
Address Register name
"
C844

Direct Inputs/Outputs (Read/Write Setting)

All except L30,
C880
L90
"
C881
2
"
C882
"
C883
"
C884

Direct Input/Output Commands (Read/Write Command)

All except L30,
C888
L90

Direct Inputs (Read/Write Setting) (32, 64, or 96 Modules)

All except L30,
C890
L90
"
C891
"
C892
"
C893
"
C894
"
C898
"
C89C
"
C8A0
"
C8A4
"
C8A8
"
C8AC
"
C8B0
"
C8B4
"
C8B8
"
C8BC
"
C8C0
"
C8C4
"
C8C8
"
C8CC
"
C8D0
"
C8D4
"
C8D8
"
C8DC
"
C8E0
"
C8E4
"
C8E8
"
C8EC
"
C8F0
"
C8F4
"
C8F8
"
C8FC
"
C900
"
C904
2-150
Remote Diagnostics Transmit
Direct Device ID
Direct I/O Channel 1 Ring Configuration
Function
Platform Direct I/O Data Rate
Direct I/O Channel 2 Ring Configuration
Function
Platform Direct I/O Crossover Function
Direct Input/Output Clear Counters
Command
Direct Input 1 Device Number
Direct Input 1 Number
Direct Input 1 Default State
Direct Input 1 Events
...Repeated for Direct Input 2
...Repeated for Direct Input 3
...Repeated for Direct Input 4
...Repeated for Direct Input 5
...Repeated for Direct Input 6
...Repeated for Direct Input 7
...Repeated for Direct Input 8
...Repeated for Direct Input 9
...Repeated for Direct Input 10
...Repeated for Direct Input 11
...Repeated for Direct Input 12
...Repeated for Direct Input 13
...Repeated for Direct Input 14
...Repeated for Direct Input 15
...Repeated for Direct Input 16
...Repeated for Direct Input 17
...Repeated for Direct Input 18
...Repeated for Direct Input 19
...Repeated for Direct Input 20
...Repeated for Direct Input 21
...Repeated for Direct Input 22
...Repeated for Direct Input 23
...Repeated for Direct Input 24
...Repeated for Direct Input 25
...Repeated for Direct Input 26
...Repeated for Direct Input 27
...Repeated for Direct Input 28
...Repeated for Direct Input 29
...Repeated for Direct Input 30
CHAPTER 2: MODBUS COMMUNICATION
Range
Units
Step
0 to 2
---
1
1 to 16
---
1
0 to 1
---
1
64 to 128
kbps
64
0 to 1
---
1
0 to 1
---
1
0 to 1
---
1
0 to 16
---
1
0 to 96
---
1
0 to 3
---
1
0 to 1
---
1
UR SERIES – COMMUNICATIONS GUIDE
Format
Default
F223
0 (NO TEST)
F001
1
F126
0 (No)
F001
64
F126
0 (No)
F102
0 (Disabled)
F126
0 (No)
F001
0
F001
0
F086
0 (Off)
F102
0 (Disabled)