CHAPTER 3: IEC 61850 COMMUNICATION
LinDfPDIF1
LNName:
data attribute
data obj.
Type
neut
CMV
neut.instCVal
Vector
neut.instCVal.mag
FLOAT32
.f
neut.instCVal.ang
FLOAT32
.f
neut.cVal
Vector
neut.cVal.mag.f
FLOAT32
neut.cVal.ang.f
FLOAT32
neut.units
Unit
neut.units.SIUnit
ENUMERATED
neut.units
ENUMERATED
.multiplier
neut.db
INT32U
neut.zeroDb
INT32U
angRef
ENUMERATED
RstA
WYE
phsθ
CMV
phsθ.instCVal
Vector
phsθ.instCVal.mag
FLOAT32
.f
phsθ.cVal
Vector
phsθ.cVal.mag.f
FLOAT32
phsθ.units
Unit
phsθ.units.SIUnit
ENUMERATED
phsθ.units
ENUMERATED
.multiplier
phsθ.db
INT32U
phsθ.zeroDb
INT32U
neut
CMV
neut.instCVal
Vector
neut.instCVal.mag
FLOAT32
.f
neut.cVal
Vector
neut.cVal.mag.f
FLOAT32
neut.units
Unit
neut.units.SIUnit
ENUMERATED
neut.units
ENUMERATED
.multiplier
neut.db
INT32U
neut.zeroDb
INT32U
angRef
ENUMERATED
InRef001
ORG
setSrcRef
ObjectReference
setSrcCB
ObjectReference
BlkRef9
ORG
UR SERIES – COMMUNICATIONS GUIDE
Prot
LDevice inst:
FC UR Name
MX
IG DIFF. CURRENT magnitude, in
primary amps
IG DIFF. CU
MX
IG DIFF. CURRENT magnitude, in
primary amps, with deadband
IG DIFF. CU
CF
CF LinDfPDIF1.DifAClc.neut.db
CF CURRENT CUT-OFF LEVEL setting
multiplied by 100000/46
CF
MX
Iθ RESTR. CURRENT magnitude, in
primary amps
MX
Iθ RESTR. CURRENT magnitude, in
primary amps, with deadband
CF
CF LinDfPDIF1.DifAClc.phsθ.db
CF CURRENT CUT-OFF LEVEL setting
multiplied by 100000/46
MX
IG RESTR. CURRENT magnitude, in
primary amps
MX
IG RESTR. CURRENT magnitude, in
primary amps, with deadband
CF
CF LinDfPDIF1.DifAClc.neut.db
CF CURRENT CUT-OFF LEVEL setting
multiplied by 100000/46
CF
SP CHNL ASYM COMP setting
SP
MODEL IMPLEMENTATION CONFORMANCE STATEMENT (MICS)
Line Differential element (ANSI 87L) phase and general
UR element:
Description
UR range -180...+180 converted to 0...360
UR range -180...+180 converted to 0...360
5, the code for amps
0, the code for a multiplier of 1
See UR product manual regarding
FREQUENCY AND PHASE REFERENCE
Restraint currents
5, the code for amps
0, the code for a multiplier of 1
5, the code for amps
0, the code for a multiplier of 1
See UR product manual regarding
FREQUENCY AND PHASE REFERENCE
CHNL ASYM COMP setting
Reference to the data attribute to input
Source GoCB of input if via GOOSE
BLOCK GPS TIME REF setting
functions
R/W/C
R
R
R
R
R
R
R
R
3
R
R
R/W/C
R
R
R
R
R
R
R
R
R
R
R
R/W/C
R
R
R
R
R
R
R
R
R
R/W/C
R
R
R
R/C
R/C
R