Digital Counter States Actual Values (Read Only Non-Volatile); Rxgoose Boolean (Read/Write Setting) (128 Modules) - GE UR Series Manual

Hide thumbs Also See for UR Series:
Table of Contents

Advertisement

CHAPTER 2: MODBUS COMMUNICATION
Products
Address Register name
"
07E4
...Repeated for IEC103 Command 26
"
07E8
...Repeated for IEC103 Command 27
"
07EC
...Repeated for IEC103 Command 28
"
07F0
...Repeated for IEC103 Command 29
"
07F4
...Repeated for IEC103 Command 30
"
07F8
...Repeated for IEC103 Command 31
"
07FC
...Repeated for IEC103 Command 32
Digital Counter States Actual Values (Read Only Non-Volatile) (8 Modules)
All except B90
0800
Digital Counter 1 Value
"
0802
Digital Counter 1 Frozen
"
0804
Digital Counter 1 Frozen Time Stamp
"
0806
Digital Counter 1 Frozen Time Stamp us
"
0808
...Repeated for Digital Counter 2
"
0810
...Repeated for Digital Counter 3
"
0818
...Repeated for Digital Counter 4
"
0820
...Repeated for Digital Counter 5
"
0828
...Repeated for Digital Counter 6
"
0830
...Repeated for Digital Counter 7
"
0838
...Repeated for Digital Counter 8
FlexStates (Read Only)
All
0900
FlexState Bits (16 items)

RxGOOSE Boolean (Read/Write Setting) (128 Modules)

All
0912
RxGOOSE Boolean 1 Default State
"
0913
RxGOOSE Boolean 1 Events
"
0914
...Repeated for RxGOOSE Boolean 2
"
0916
...Repeated for RxGOOSE Boolean 3
"
0918
...Repeated for RxGOOSE Boolean 4
"
091A
...Repeated for RxGOOSE Boolean 5
"
091C
...Repeated for RxGOOSE Boolean 6
"
091E
...Repeated for RxGOOSE Boolean 7
"
0920
...Repeated for RxGOOSE Boolean 8
"
0922
...Repeated for RxGOOSE Boolean 9
"
0924
...Repeated for RxGOOSE Boolean 10
"
0926
...Repeated for RxGOOSE Boolean 11
"
0928
...Repeated for RxGOOSE Boolean 12
"
092A
...Repeated for RxGOOSE Boolean 13
"
092C
...Repeated for RxGOOSE Boolean 14
"
092E
...Repeated for RxGOOSE Boolean 15
"
0930
...Repeated for RxGOOSE Boolean 16
"
0932
...Repeated for RxGOOSE Boolean 17
"
0934
...Repeated for RxGOOSE Boolean 18
"
0936
...Repeated for RxGOOSE Boolean 19
"
0938
...Repeated for RxGOOSE Boolean 20
"
093A
...Repeated for RxGOOSE Boolean 21
"
093C
...Repeated for RxGOOSE Boolean 22
UR SERIES – COMMUNICATIONS GUIDE
Range
Units
Step
-2147483647 to
---
1
2147483647
-2147483647 to
---
1
2147483647
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 65535
---
1
0 to 3
---
1
0 to 1
---
1
MEMORY MAP
Format
Default
F004
0
F004
0
F050
0
F003
0
F001
0
F086
0 (Off)
F102
0 (Disabled)
2-15
2