Transformer Thermal Inputs (Read/Write Command); Transformer Percent Differential (Read/Write Grouped Setting); Transformer Inst Differential (Read/Write Grouped Setting); Autoreclose (Read/Write Setting) (1, 2, Or 6 Modules) - GE UR Series Manual

Hide thumbs Also See for UR Series:
Table of Contents

Advertisement

CHAPTER 2: MODBUS COMMUNICATION
Products
Address Register name
"
6171
Ambient Temperature Input Sensor
"
6172
Top Oil Temperature Input Sensor
"
6173
January Average Ambient Temperature
"
6174
February Average Ambient Temperature
"
6175
March Average Ambient Temperature
"
6176
April Average Ambient Temperature
"
6177
May Average Ambient Temperature
"
6178
June Average Ambient Temperature
"
6179
July Average Ambient Temperature
"
617A
August Average Ambient Temperature
"
617B
September Average Ambient Temperature -60 to 60
"
617C
October Average Ambient Temperature
"
617D
November Average Ambient Temperature
"
617E
December Average Ambient Temperature

Transformer Thermal Inputs (Read/Write Command)

T60
6180
Transformer Loss of Life Clear Command

Transformer Percent Differential (Read/Write Grouped Setting)

G30, T35, T60
61C0
Percent Differential Function
"
61C1
Percent Differential Pickup
"
61C2
Percent Differential Slope 1
"
61C3
Percent Differential Break 1
"
61C4
Percent Differential Break 2
"
61C5
Percent Differential Slope 2
"
61C6
Inrush Inhibit Function
"
61C7
Inrush Inhibit Level
"
61C8
Overexcitation Inhibit Function
"
61C9
Overexcitation Inhibit Level
"
61CA
Percent Differential Block
"
61CC
Percent Differential Target
"
61CD
Percent Differential Events
"
61CE
Transformer Inrush Inhibit Mode

Transformer Inst Differential (Read/Write Grouped Setting)

T35, T60
61DA
Inst Differential Function
"
61DB
Inst Differential Pickup
"
61DC
Inst Differential Block
"
61DE
Inst Differential Target
"
61DF
Inst Differential Events

Autoreclose (Read/Write Setting) (1, 2, or 6 Modules)

D30, F35, F60,
6200
Autoreclose 1 Function
L30
"
6201
Autoreclose 1 Initiate
"
6203
Autoreclose 1 Block
"
6205
Autoreclose 1 Max Number of Shots
"
6206
Autoreclose 1 Manual Close
"
6208
Autoreclose 1 Manual Reset from LO
"
620A
Autoreclose 1 Reset Lockout if Breaker
Closed
UR SERIES – COMMUNICATIONS GUIDE
Range
Units
Step
0 to 32
---
1
0 to 32
---
1
-60 to 60
°C
1
-60 to 60
°C
1
-60 to 60
°C
1
-60 to 60
°C
1
-60 to 60
°C
1
-60 to 60
°C
1
-60 to 60
°C
1
-60 to 60
°C
1
°C
1
-60 to 60
°C
1
-60 to 60
°C
1
-60 to 60
°C
1
0 to 1
---
1
0 to 1
---
1
0.050 to 1.000
pu
0.001 F001
15 to 100
%
1
1 to 2
pu
0.001 F001
2 to 30
pu
0.001 F001
50 to 100
%
1
0 to 2
---
1
1 to 40
%f
0.1
o
0 to 1
---
1
1 to 40
%f
0.1
o
0 to 4294967295
---
1
0 to 2
---
1
0 to 1
---
1
0 to 2
---
1
0 to 1
---
1
2 to 30
pu
0.001 F001
0 to 4294967295
---
1
0 to 2
---
1
0 to 1
---
1
0 to 1
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
1 to 4
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 1
---
1
MEMORY MAP
Format
Default
F450
0
F460
0
F002
-20
F002
-30
F002
-10
F002
10
F002
20
F002
30
F002
30
F002
30
F002
20
F002
10
F002
10
F002
-10
F126
0 (No)
F102
0 (Disabled)
100
F001
25
2000
8000
F001
100
F168
1 (Adapt.
2nd)
F001
200
F169
0 (Disabled)
F001
100
F300
0
F109
0 (Self-reset)
F102
0 (Disabled)
F189
0 (Per phase)
F102
0 (Disabled)
8000
F300
0
F109
0 (Self-reset)
F102
0 (Disabled)
F102
0 (Disabled)
F300
0
F300
0
F001
1
F300
0
F300
0
F108
0 (Off)
2-73
2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents