MODEL IMPLEMENTATION CONFORMANCE STATEMENT (MICS)
Data object
CDC
name
LivLiv
SPS
LivLivDpo
SPS
LivV1
SPS
LosLife
MV
LosLifeRte
MV
LosPkt1
SPS
MAC
VSG
MajorErr
SPS
3
MaxAsymOp1
SPS
MinorErr
SPS
MnlCls
SPS
NegTotVArh
MV
NegTotWh
MV
NeutOpn
SPS
NeutSupn
SPS
NumCycPer
INS
Off
SPS
On
SPS
OnePoleOpn
SPS
OnePU
ASG
OpBia
ACT
OpHiSet
ACT
OpLoSet
ACT
OpnSt1
SPS
OpPhs1
SPS
OpSig
MV
OpUnBia
ACT
OscilGOOSE
SPS
OutOfSrv
SPS
P1Rip
SPS
P3Rip1
SPS
P3Tr
SPS
PbCtl
ENG
PFLLfail
SPS
PhDir1
SPS
PosTotVArh
MV
PosTotWh
MV
3-132
Semantics
This data object indicates that both sources are live, and that angle, frequency, and
voltage difference and range conditions have been met
This data object indicates that one or both sources are not live, or that angle,
frequency, and voltage difference and range conditions have been met
This data object indicates that V1 is above the LivVal1 setting
The lost packet threshold has been exceeded
Expected value of Destination MAC address field in messages subscribed to by
RxGOOSE#
Any of the major self-test errors generated (major error)
Asymmetry on the channel exceeded pre-set value
Any of the minor self-test errors generated (minor error)
Manual close initiated
Total VAr-hour in negative direction
Total Watt-hour in negative direction
Indicates source has lost voltage signal
Neutral overcurrent supervision status
Number of cycles of the nominal frequency
Logic 0 fixed operand
Logic 1 fixed operand
One pole is open, others closed
The per-unit base factor applied to the corresponding RxGOOSE analog input
FlexAnalog quantity to normalize it to a per-unit quantity.
B90 Operate indicates the trip decision of a biased protection logic
B90 Operate indicates the trip decision of the HISET element of breaker failure current
supervision function.
B90 Operate indicates the trip decision of the LOSET element of breaker failure current
supervision function.
Open status detected
Indicates a trip decision for a particular cause per phase
Operating signal, the analogue value used by the comparator
B90 Operate indicates the trip decision of an unbiased protection logic
One or more of GGIO1.Ind###.stVal has been frozen due to frequent status changes
(chatter) in the mapped operand
Out-of-service
Autoreclose A single pole is in progress
Autoreclose 3-pole is in progress via dead time number indicated by the data instance
number
Force any trip to 3-phase trip
Front panel pushbutton control Enable/Disable setting: 0 = Disabled, 1 = Enabled
Phase and/or frequency lock loop (PFLL) has failed
Indicates Phase Comparison of differential is satisfied per phase, where the last digit of
instance number 1, 2, or 3 refers to phase A, B, and C respectively
Total VAr-hour in positive direction
Total Watt-hour in positive direction
CHAPTER 3: IEC 61850 COMMUNICATION
Used in logical
nodes...
SynChkRSYN
SynChkRSYN
SynChkRSYN
LosLifSPTR1
LosLifSPTR1
LinDfPDIF
LGOS
LPHD
LinDfPDIF
LPHD
Bkr?XCBR
EnrMtrMMTR
EnrMtrMMTR
VtffGAPC
GndDisPDIS
OscRDRE
Master/LLN0
Master/LLN0
Bkr?XCBR
GGIO3
B_DifPDIF
B_BFaiPIOC
B_BFaiPIOC
Bkr?XCBR,
Disc0XSWI,
Disc?XSWI, GGIO3
BusDifPDIF,
PhsDisPDIS
FlxElGAPC
B_DifPDIF
LPHD
Bkr?XCBR
Rec13pRREC
Rec13pRREC
Rec13pRREC
Bkr?XCBR
LinDfPDIF
B_DifPDIF,
BusDifPDIF,
SttDifPDIF
EnrMtrMMTR
EnrMtrMMTR
UR SERIES – COMMUNICATIONS GUIDE