Wattmetric Ground Fault Settings (Read/Write Grouped) (2 Or 4 Modules); Wattmetric Ground Fault Actual Values (Read Only) (2 Or 4 Modules); Iec 61850 Xswi Configuration (Read/Write Setting) (24 Modules) - GE UR Series Manual

Hide thumbs Also See for UR Series:
Table of Contents

Advertisement

CHAPTER 2: MODBUS COMMUNICATION
Products
Address Register name
"
B244
...Repeated for Received Analog 27
"
B246
...Repeated for Received Analog 28
"
B248
...Repeated for Received Analog 29
"
B24A
...Repeated for Received Analog 30
"
B24C
...Repeated for Received Analog 31
"
B24E
...Repeated for Received Analog 32

Wattmetric Ground Fault Settings (Read/Write Grouped) (2 or 4 Modules)

D60, F35, F60,
B300
Wattmetric Ground Fault 1 Function
L60, L90
"
B301
Wattmetric Ground Fault 1 Source
"
B302
Wattmetric Ground Fault 1 Voltage
"
B303
Wattmetric Ground Fault 1 Overvoltage
Pickup
"
B304
Wattmetric Ground Fault 1 Current
"
B305
Wattmetric Ground Fault 1 Overcurrent
Pickup
"
B306
Wattmetric Ground Fault 1 Overcurrent
Pickup Delay
"
B307
Wattmetric Ground Fault 1 Power Pickup
"
B308
Wattmetric Ground Fault 1 ECA
"
B309
Wattmetric Ground Fault 1 Power Pickup
Delay
"
B30A
Wattmetric Ground Fault 1 Curve
"
B30B
Wattmetric Ground Fault 1 Multiplier
"
B30C
Wattmetric Ground Fault 1 Block
"
B30E
Wattmetric Ground Fault 1 Target
"
B30F
Wattmetric Ground Fault 1 Events
"
B310
Wattmetric Ground Fault 1 Reference
Power
"
B311
Wattmetric Ground Fault 1 Reserved
"
B312
...Repeated for Wattmetric Ground Fault 2
F35
B324
...Repeated for Wattmetric Ground Fault 3
"
B336
...Repeated for Wattmetric Ground Fault 4

Wattmetric Ground Fault Actual Values (Read Only) (2 or 4 Modules)

D60, F35, F60,
B360
Wattmetric Ground Fault 1 Operating
L60, L90
Power
"
B362
...Repeated for Wattmetric Ground Fault 2
F35
B364
...Repeated for Wattmetric Ground Fault 3
"
B366
...Repeated for Wattmetric Ground Fault 4

IEC 61850 XSWI Configuration (Read/Write Setting) (24 Modules)

All except B90
B370
FlexLogic Operand for IEC 61850
XSWI.ST.Loc Status
"
B372
FlexLogic Operand for IEC 61850 XSWI
Open Interlock
"
B374
FlexLogic Operand for IEC 61850 XSW
Close Interlock
"
B376
...Repeated for Switch 2
UR SERIES – COMMUNICATIONS GUIDE
Range
Units
Step
0 to 1
---
1
0 to 5
---
1
0 to 1
---
1
0.02 to 3.00
pu
0.01
0 to 1
---
1
0.002 to 30.000
pu
0.001 F001
0 to 600
s
0.01
0.001 to 1.2
pu
0.001 F001
0 to 360
° Lag
1
0 to 600
s
0.01
0 to 5
---
1
0.01 to 2
s
0.01
0 to 4294967295
---
1
0 to 2
---
1
0 to 1
---
1
0.001 to 1.2
pu
0.001 F001
0 to 1
---
1
0 to 999999.999
W
0.001 F060
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
MEMORY MAP
Format
Default
F102
0 (Disabled)
F167
0 (SRC 1)
F234
0
(Calculated
VN)
F001
20
F235
0
(Calculated
IN)
60
F001
20
100
F001
0
F001
20
F236
0 (Definite
Time)
F001
100
F300
0
F109
0 (Self-reset)
F102
0 (Disabled)
500
F001
0
0
F300
0
F300
1
F300
1
2-139
2