CHAPTER 3: IEC 61850 COMMUNICATION
BkrΘXCBR#
LNName:
data attribute
data obj.
Type
setSrcRef
ObjectReference
setSrcCB
ObjectReference
InRef2
ORG
setSrcRef
ObjectReference
setSrcCB
ObjectReference

3.5.4.5 Contact input interface (ConIn)

This element is instantiated in all UR products (B30, B90, C30, C60, C70, D30, D60, F35, F60, G30, G60, L30, L60, L90, M60,
N60, T35, T60).
Table 3-94: Contact input data objects
ConInGGIO1
LNName:
data attribute
data obj.
Type
Ind1Θ
SPS
stVal
BOOLEAN
Ind2Θ
SPS
stVal
BOOLEAN

3.5.4.6 Contact output interface (ConOut)

This element is instantiated in all UR products (B30, B90, C30, C60, C70, D30, D60, F35, F60, G30, G60, L30, L60, L90, M60,
N60, T35, T60).
Table 3-95: Contact output data objects
ConOutGGIO1
LNName:
data attribute
data obj.
Type
Ind1Θ
SPS
stVal
BOOLEAN
Ind2Θ
SPS
stVal
BOOLEAN
Ind3Θ
SPS
stVal
BOOLEAN
InRef1Θ
ORG
setSrcRef
ObjectReference
setSrcCB
ObjectReference
InRef2Θ
ORG
setSrcRef
ObjectReference
setSrcCB
ObjectReference
UR SERIES – COMMUNICATIONS GUIDE
System
LDevice inst:
FC UR Name
SP BREAKER # φA/3P CLSD if Θ="1",
BREAKER # φB CLSD if Θ="2", or
BREAKER # φC CLSD if Θ="3"
SP
SP BREAKER # φA/3P OPND if Θ="1",
BREAKER # φB OPND if Θ="2", or
BREAKER # φC OPND if Θ="3"
SP
System
LDevice inst:
FC UR Name
ST Cont Ip φ On
ST Cont Ip φ Off
System
LDevice inst:
FC UR Name
ST Cont Op φ IOn
ST Cont Op φ VOn
ST Cont Op φ VOff
SP CONTACT OUTPUT φ OPERATE
setting
SP
SP CONTACT OUTPUT φ SEAL-IN
setting
SP
MODEL IMPLEMENTATION CONFORMANCE STATEMENT (MICS)
UR element:
Description
Reference to the data attribute to input
Source GoCB of input if via GOOSE
BREAKER # φA/3P OPND setting" if Θ="1",
"BREAKER # φB OPND setting" if Θ="2", or
"BREAKER # φC OPND setting" if Θ="3
Reference to the data attribute to input
Source GoCB of input if via GOOSE
Description
Concatenation of value of CONTACT INPUT
φ ID + " On (φ) operand value
Concatenation of value of CONTACT INPUT
φ ID + " Off (φ) operand value
Description
Only instantiated where the order code
indicates that contact output Θ is equipped
with a current detector
Only instantiated where the order code
indicates that contact output Θ is equipped
with a voltage detector
Only instantiated where the order code
indicates that contact output Θ is equipped
with a voltage detector
CONTACT OUTPUT φ OPERATE setting
Reference to the data attribute to input
Source GoCB of input if via GOOSE
CONTACT OUTPUT φ SEAL-IN setting.
Reference to the data attribute to input
Source GoCB of input if via GOOSE
Breaker Control element #
R/W/C
R/C
R/C
R
R/C
R/C
Contact Inputs
UR element:
R/W/C
R
R
R
R
Contact Outputs
UR element:
R/W/C
R
R
R
R
R
R
R
R/C
R/C
R
R/C
R/C