Lines Rate A / B - GRAUPNER mz-24 Pro Programming Manual

12 channel hott 2,4 ghz transmitter
Hide thumbs Also See for mz-24 Pro:
Table of Contents

Advertisement

Notice
If you switch, through the switch assigned
here,
OFF
, you turn off not only the phase
trim described here, but at the same time the
functions described at the begin of this section under
INH
OFF
"ACT" =
or
.

Lines RATE A / B

A symmetrical or an asymmetrical effect can be de-
fined for each flap pair. If in the
CTL Set
you leave (have left) the travel settings of the switch
assigned to the flap trimming to +100 %, then here
you can input values within 5 and 20 % which should
be enough.
Switch to the desired phase, and touch the value field
to be set with a finger or the provided stylus:
BACK
THERMAL
Flap set
ACT
ON
CTL
SW 6
AILE1
AILE2
RATE A
000%
000%
000%
000%
RATE B
Touch
The color of the value field switches from black to
blue:
BACK
THERMAL
Flap set
ACT
ON
CTL
SW 6
AILE1
AILE2
RATE A
000%
000%
RATE B
000%
000%
198 Function menu | Airplane models - Flaps settings
In the active (blue) value field, press
the current value within a range of ±100% and
reduce it, for example:
BACK
ACT
RATE A
RATE B
sub-menu
Use same procedure with the other values to be set,
as well as any inboard aileron "AILE2L" and "AILE2R".
Touch the
RES
blue (and hence active) field to the default value.
After completing the settings for the ailerons, you
can switch to the page for setting the flaps by touch-
SERVO
ing
NEXT
at the right edge of the display to set the
flaps and enter the desired settings using the proce-
NEXT
dure described above, for example:
INC
BACK
RES
ACT
DEC
RATE A
RATE B
SERVO
Finally, you can switch to the page for setting the ele-
NEXT
vator by touching
INC
play to set the elevator and enter the desired settings
RES
using the procedure described above, for example:
DEC
+
to increase
THERMAL
Flap set
SERVO
ON
CTL
SW 6
NEXT
INC
AILE1
AILE2
+010%
000%
RES
DEC
000%
000%
button to reset a changed value in the
THERMAL
Flap set
SERVO
ON
CTL
SW 6
NEXT
INC
FLAP1
FLAP3 FLAP4
FLAP2
+020%
RES
+025%
+025%
+020%
+020%
+025%
+025%
+020%
DEC
NEXT
at the right edge of the dis-
BACK
THERMAL
to
ACT
ON
CTL
ELEV1
RATE A
+005%
RATE B
+005%
Tip
Standardly in the
"CTL
Set" sub-menu to the inputs
"CH5 ... CH12" NO control is assigned. However, you
can assign a control or switch at any time and hence
set different flap positions within a phase as described
in this section. In contrast the
described in the "program examples" allows to trim the
flaps specifically for the phases through only one control
element within all the phases.
After you have finished making your settings, touch
BACK
the
button at the top left of the display to return
to the menu selection.
Flap set
SERVO
SW 6
NEXT
INC
RES
DEC
Variant of a flaps trimming

Advertisement

Table of Contents
loading

Table of Contents