Ctrl/Sw Option - GRAUPNER mz-24 Pro Programming Manual

12 channel hott 2,4 ghz transmitter
Hide thumbs Also See for mz-24 Pro:
Table of Contents

Advertisement

Set" a switch or a con-
If in the sub-menu
"CTL
trol has been assigned to the output "CH6",
for example the left proportional control lever
"SL2" ...
BACK
PHASE 1
CTL Set
CH 5.
NONE
000%
+100% +100%
CH 6.
SL 2
000%
+100%
+100%
CH 7.
NONE
000%
+100%
+100%
CH 8.
NONE
000%
+100%
+100%
CTL
OFFSET
– Travel +
... then all the provided flaps move in the po-
sition corresponding to the control position
("CTL
Set"), offset value and travel setting so
as
("Flap
MIX") RATE and offset values of the
respective flaps positions.
Notice
Set therefore the clarity as far as possible
only in one of the involved sub-menus val-
ue.
• "ACT" =
ON
As long as "ACT" is activated ...
BACK
PHASE 1
Flap Set
ACT
ON
CTL
ON
AILE1
AILE2
RATE A
000%
000%
RATE B
000%
000%
... only the standard or previously customized
offset values of the "aileron" option of the
MIX" sub-menu are valid ...
BACK
FLAP
SERVO
RATE A
RATE B
NEXT
OFFSET
INC
... so as the following described RATE setting
RES
of the "AILERON" display page of the
DEC
set" sub-menu ...
BACK
ACT
RATE A
RATE B
... on the standard flap servos 6 and 7 so as 9
and 10, or in case of a model with only one flap
servo only to the servo 6.
If in the sub-menu
trol has been assigned to the output "CH6",
for example the left proportional control lever
"SL2" so as an offset value, e.g. ...
SERVO
BACK
NEXT
INC
K 5.
RES
K 6.
DEC
K 7.
K 8.
"Flap
... then all the provided flaps move to the con-
trol position
PHASE 1
FLAP MIX
SERVO
INC
FLAP1
FLAP3 FLAP4
FLAP2
+100%
+100%
+100%
+100%
RES
DEC
+100%
+100%
+100%
+100%
000%
000%
000%
000%
"Flap
PHASE 1
Flap set
SERVO
ON
CTL
ON
NEXT
FLAP1
FLAP2
INC
000%
000%
RES
000%
000%
DEC
"CTL
Set" a switch or a con-
PHASE 1
CTL Set
SERVO
NONE
000%
+100% +100%
NEXT
SL 2
+015%
INC
+100%
+100%
NONE
000%
+100%
+100%
RES
DEC
NONE
000%
+100%
+100%
CTL
OFFSET
– TRAVEL+
("CTL
Set"),
Offset and travel settings so as to the RATE val-
ues of the following described aileron displays
set" sub menu. And all the flaps
of the
"Flap
accordingly to the addiction of
control position, offset value and travel settings
so as
("Flap
MIX") offset and the RATE values
of the following described aileron display of the
"Flap
set" sub-menu.
Notice
Set the clarity as far as possible only in one
of the involved sub-menus value.
In the displays described below, you
specify the effect of the control elements assigned
to channel 6 in the
"CTL
Set" sub-menu, in the
form of a phase trim on the positions of the aile-
rons, flaps, and possibly the elevators.

• Ctrl/sw option

In the value field in the Ctrl/sw column, you as-
sign a control or control switch for a specific phase
to the mixer as described in the section
and switch
assignment, for example in the phase
"THERMAL":
BACK
THERMAL
Flap set
ACT
ON
CTL
AILE1
000%
RATE A
RATE B
000%
Function menu | Airplane models - Flaps settings
("CTL
Set")
(control/switch)
Control
SERVO
SW 6
NEXT
INC
AILE2
RES
000%
000%
DEC
197

Advertisement

Table of Contents
loading

Table of Contents