Use the same procedure for the other settings.
Notices
• The controllers assigned in this sub-menu
globally affect all the phases. Only the offset in
the second line and the "travel setting" in the
third and fourth column affect specific phases.
• If, with a model that has flaps, you assign to
input 6 a control or switch identified as
"FLAP(1L)", its function is dependent on the
current setting in the line "ACT" of the sub-
Sett" of the function menu (page
menu
"Flap
). If the value field to the right of "ACT" is
OFF
or
, then this control or switch acts ex-
clusively on servo 6 and possibly 7 with the
values set in the sub-menu "D/R,Exp". Other-
wise, this control or switch assumes the func-
tion of Q.Link trimming with the value set in
the sub-menu
"Flap
Sett".
Phase depending settings
In contrast to the previously described - phase influ-
encing - control and switch assignation in the "CTL
Set" column the values act in the following described
columns "OFFSET" and "-Travel+" so as the phase
specific "symmetrical delay" which are available in a
specific page. Recognizable on the top left side of the
display in green color is displayed the phase name. As
standard is displayed the name of the phase 1, which
is indicated by the name "NORMAL" or "PHASE 1".
As soon as you will have defined one or many oth-
er phases in the "PHASE" menu, you will be able to
switch among those phases. Activate the correspond-
ing switch or switches if desired to switch between
the phases.
92
Base menu - Control/switch setting

"OFFSET" column

Change the center of each control element, i.e., its
zero point (if desired with reference to a specific
phase), in this column.
Touch the offset value to be changed, for example:
BACK
PHASE 1
CH 5.
NONE
000%
CH 6.
NONE
000%
Touch
CH 7.
NONE
000%
CH 8.
DV 2
000%
INH
CTL
OFFSET
The color of the value field switches from black to
blue:
BACK
PHASE 1
CH 5.
NONE
000%
CH 6.
NONE
000%
CH 7.
NONE
000%
CH 8.
DV 2
000%
CTL
OFFSET
Set the desired value with the
right edge, for example:
BACK
PHASE 1
CH 5.
NONE
000%
CH 6.
NONE
000%
CH 7.
NONE
000%
CH 8.
DV 2
+012%
CTL
OFFSET
The adjustment range is ±125%.
Touch the
blue (and hence active) field to the default value.
Use the same procedure for the other settings.

"- Travel+" column

In this column is set the travel of each control ele-
ment, specifically for each page.
CTL Set
SERVO
Touch the left value field in the corresponding line to
set a value to the minus side of the control travel, and/
+100% +100%
NEXT
or on the right to set a value on the plus side of the
INC
+100%
+100%
control travel, for example:
+100%
+100%
RES
DEC
+100%
+100%
– TRAVEL+
SERVO
CTL Set
100%
100%
NEXT
The color of the field switches from black to blue:
+100%
+100%
INC
+100%
+100%
RES
+100%
+100%
DEC
– TRAVEL+
+
or
button at the
SERVO
CTL Set
Set the desired value with the
100%
100%
NEXT
right edge.
+100%
+100%
INC
The adjustment range is ±125%.
+100%
+100%
RES
DEC
Use the same procedure for a value on the plus side
+100%
+100%
of the control travel, for example:
– TRAVEL+
RES
button to reset a changed value in the
BACK
PHASE 1
CTL Set
SERVO
CH 5.
NONE
000%
100%
100%
NEXT
INC
CH 6.
NONE
000%
+100%
+100%
Touch
CH 7.
NONE
000%
+100%
+100%
RES
DEC
CH 8.
DV 2
+012%
+100%
+100%
CTL
OFFSET
– TRAVEL+
BACK
PHASE 1
CTL Set
SERVO
CH 5.
NONE
000%
100%
100%
NEXT
INC
CH 6.
NONE
000%
+100%
+100%
CH 7.
NONE
000%
+100%
+100%
RES
CH 8.
DV 2
+012%
+100%
+100%
DEC
CTL
OFFSET
– TRAVEL+
+
or
button at the

Advertisement

Table of Contents
loading

Table of Contents