Clear The Carloss Alarm; Chanloss; Clear The Chanloss Condition - Cisco ONS 15600 SDH Troubleshooting Manual

Hide thumbs Also See for Cisco ONS 15600 SDH:
Table of Contents

Advertisement

2.6.22 CHANLOSS

Clear the CARLOSS Alarm

Ensure that the GIGE client is correctly configured by completing the following steps:
Step 1
a.
b.
c.
d.
If there is no SFP (PPM) misprovisioning, check for a fiber cut.
Step 2
If there is no fiber cut or provisioning error, check the client-side equipment for any transmission errors
Step 3
on the line.
If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/techsupport
Step 4
for more information or call Cisco TAC (1 800 553-2447) in order to report a Service-Affecting (SA)
problem.
2.6.22 CHANLOSS
The SDH Section Layer DCC Termination Failure condition occurs when the ONS 15600 SDH receives
unrecognized data in the section layer DCC bytes.
Invisible laser radiation could be emitted from the end of the unterminated fiber cable or connector.
Warning
Do not stare into the beam directly with optical instruments. Viewing the laser output with certain
optical instruments (for example, eye loupes, magnifiers, and microscopes) within a distance of
100 mm could pose an eye hazard. Statement 1056
Warning
Use of controls, adjustments, or performing procedures other than those specified may result in
hazardous radiation exposure. Statement 1057

Clear the CHANLOSS Condition

Step 1
In the absence of other alarms, determine whether the alarmed port is connected to another vendor's
equipment. If so, you can mask the alarm on this path using a custom alarm profile. For more information
about custom profiles, refer to the "Manage Alarms" chapter in the Cisco ONS 15600 SDH Procedure
Guide.
Cisco ONS 15600 SDH Troubleshooting Guide, R8.0
2-28
Double-click the ASAP card to display the card view.
Click the Provisioning > Pluggable Port Modules tabs.
View the Pluggable Port Modules area port listing in the Actual Equipment Type column and
compare this with the client equipment. If no SFP (referred to as a PPM in CTC) is provisioned,
refer to the "Install Cards and Fiber-Optic Cable" chapter in the Cisco ONS 15600 SDH Procedure
Guide for provisioning instructions.
If an SFP (PPM) has been created, view the contents of the Selected PPM area Rate column for the
port and compare this rate with the client equipment data rate. In this case, the rate should be
ETHER. If the SFP (PPM) rate is differently provisioned, select the SFP (PPM), click Delete, then
click Create and choose the correct rate for the equipment type.
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
Logical Object: STMN
Chapter 2 Alarm Troubleshooting
July 2010