Cisco ONS 15600 SDH Troubleshooting Manual page 269

Hide thumbs Also See for Cisco ONS 15600 SDH:
Table of Contents

Advertisement

Chapter 4 Error Messages
Table 4-1
Error Messages (continued)
Error Warning
ID
Error Warning Message
EID-2188
The nodes in this ring do not support alphanumeric IDs. Please
use a ring ID between {0} and {1}.
EID-2189
The TL1 keyword "all" cannot be used as the ring name.
Please provide another name.
EID-2190
Adding this span will cause the ring to contain more nodes than
allowed.
EID-2191
The ring name must not be empty.
EID-2192
A valid route cannot be found for the circuit creation request.
EID-2193
A valid route cannot be found for the circuit drop creation
request.
EID-2194
A valid route cannot be found for the roll creation request.
EID-2195
The circuit VLAN list cannot be mapped to one spanning tree.
You can view the VLAN/Spanning Tree table or reassign
VLANs.
EID-2196
CTC cannot be relaunched.
{0}
EID-2197
A CORBA failure occurred. CTC cannot proceed.
EID-2198
CTC is unable to switch to the {0} view.
EID-2199
Login failed on {0} {1}
EID-2200
CTC has detected a jar file deletion. The jar file was used to
manage one or more nodes. This CTC session will not be able
to manage those nodes and they will appear gray on the network
map. It is recommended that you exit this CTC session and start
a new one.
EID-2202
An intra-node DRI circuit must have two sources.
EID-2203
No member was selected.
EID-2204
The number of circuits must be a positive integer.
EID-2205
The circuit type must be selected.
EID-2206
The profile cannot be autoselected. Please select profile(s) to
store and try again.
EID-2207
You cannot add this span. Either the ring name is too long (that
is, ring name length is greater than {0}) or the endpoints do not
support alphanumeric IDs.
July 2010
Description
The ring ID should not contain
alphanumeric characters, and must be in the
specified range.
Refer to the error message text.
You have reached the maximum number of
nodes allowed.
You must supply a ring name.
CTC could not complete the circuit creation
request either beacuse there are no physical
links, or the bandwidth of the available
links are already reserved.
Refer to the error message text.
Refer to the error message text.
Refer to the error message text.
There is an error relaunching CTC.
There was a CORBA failure, and the task
cannot proceed. Verify the Java version.
CTC is unable to switch to the specified
view.
The login failed on the specified tasks.
Refer to the error message text.
Intranode circuit must have two sources to
be a dual ring interconnect (DRI).
You must select a member.
The number of circuits cannot be zero or
negative.
You must select a circuit type.
Refer to the error message text.
Reduce the length of the ring name, or
remove the alphanumberic characters from
the endpoints.
Cisco ONS 15600 SDH Troubleshooting Guide, R8.0