If the fan tray does not run immediately, troubleshoot with the
Step 2
on page
Step 3
If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/techsupport
for more information or call Cisco TAC (1 800 553-2447).
2.6.103 IMPR-XC
The Improper Cross-Connect Card alarm indicates that the CXC card is being used rather than the SSXC
(the preferred cross-connect card for Software R5.0 and later). The alarm remains standing as long as a
CXC is present on the node. Since a CXC card is still capable of passing traffic, the alarm is not
Service-Affecting (SA). However, a system containing a CXC card and the current software release is
not fully guaranteed for functionality.
IMPR-XC is an informational alarm and does not require troubleshooting. However, if you are
Note
experiencing cross-connect related problems at this site, also report this alarm to the Cisco TAC.

2.6.104 INCOMPATIBLE-SEND-PDIP

The Incompatible Send-PDIP alarm is raised when CTC's send-PDIP provisioning differs from the host
node's provisioning.

Clear the INCOMPATIBLE-SEND-PDIP Alarm

Reconfigure CTC's send-PDI-P alarm capability to align with the host node settings.
Step 1
Step 2
If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/techsupport
for more information or call Cisco TAC (1-800-553-2447).

2.6.105 INCOMPATIBLE-SW

The Incompatible Software alarm is raised when CTC cannot connect to the NE due to incompatible
versions of software between CTC and the NE. The alarm is cleared by restarting CTC in order to
redownload the CTC JAR files from the NE.
Cisco ONS 15600 SDH Troubleshooting Guide, R8.0
2-74
2-57.
Default Severity: Minor (MN), Non-Service-Affecting (NSA)
Logical Object: NE
Default Severity: Minor (MN), Non-Service-Affecting (NSA)
Logical Object: SYSTEM
Default Severity: Minor (MN), Non-Service-Affecting (NSA)
Logical Object: SYSTEM
Chapter 2 Alarm Troubleshooting
"Clear the FAN-FAIL Alarm" procedure