Cisco ONS 15600 SDH Troubleshooting Manual page 292

Hide thumbs Also See for Cisco ONS 15600 SDH:
Table of Contents

Advertisement

Table 4-1
Error Messages (continued)
Error Warning
ID
Error Warning Message
EID-5049
Provisionable patchcords created between gray OC-N trunk
ports and multiplexer/demultiplexer ports are not supported.
EID-5050
The element model could not be found.
{0}
WID-5051
The port state cannot be indirectly transitioned because the port
aggregates OCHCC circuits: if the port state needs to be
changed, edit it directly through port provisioning.
EID-5052
The operation is not valid for the connection type.
EID-5053
The operation cannot be performed because the connection is
under test access.
EID-5054
The TL1 tunnel could not be opened. {0}
EID-5055
Some patchcords were not deleted. Patchcords cannot be
deleted if they are incomplete or support any circuits, or if the
nodes supporting them are not connected.
EID-5056
This PPC cannot be deleted because one or more circuits are
provisioned over it.
EID-5057
The addition of the last node has not yet finished.
Please wait before trying to add a new node.
EID-5058
An OCHNC upgrade is applicable only to bidirectional circuits. Refer to the error message text.
EID-5059
The OCHNC upgrade failed.
One or more communication failures occurred during the
operation.
EID-5060
The OCHNC upgrade partially failed.
One or more communication failures occurred during the
operation.
Create the OCHCC manually.
EID-5061
The overhead circuit source and destination must reside on the
same shelf.
EID-5062
A four-fiber {0} cannot be created using three cards.
WID-5063
The profile "{0}" includes a change to the OPEN-SLOT alarm
severity.
This change is disallowed for the ONS 15600. "{1}" will
continue to use the OPEN-SLOT severity of MN that is
included in the default configuration.
Other changes from the "{2}" profile were successfully applied
to {3}".
EID-5064
{0}
{1}
Cisco ONS 15600 SDH Troubleshooting Guide, R8.0
4-36
Chapter 4 Error Messages
Description
Refer to the error message text.
The specified element model cannot be
located.
Refer to the warning message text.
You might have selected the incorrect
switch.
Refer to the error message text.
Refer to the error message text.
Refer to the error message text.
Remove the circuits provisioned over the
provisionable patchcord before trying to
delete it.
Refer to the error message text.
CTC encountered a complete failure while
upgrading optical channel network
connection.
CTC encountered a partial failure while
upgrading an optical channel network
connection.
Refer to the error message text.
A four-fiber MS-SPRing needs four cards.
Refer to the warning message text.
This indicates the status of SNCP
switching.
July 2010