Cisco ONS 15600 SDH Troubleshooting Manual page 294

Hide thumbs Also See for Cisco ONS 15600 SDH:
Table of Contents

Advertisement

Table 4-1
Error Messages (continued)
Error Warning
ID
Error Warning Message
EID-5082
{0} does not support:
- Low-order circuits that have both {1}-protected and
{2}-protected spans and that cross a node that does not have
low-order cross-connect capability.
- High-order circuits that carry low-order circuits with the
parameters described above.
EID-5083
This circuit is not the same size as the existing circuit {0}.
This circuit has size {1} and the existing circuit has size {2}.
EID-5084
The Trunk model could not be found.
{0}
EID-5085
The maximum number of VLAN DB profiles is {0}.
EID-5086
The circuit roll failed.
You cannot bridge and roll the selected circuit because it has a
monitor circuit.
EID-6000
This platform does not support power monitoring thresholds.
EID-6001
One of the XC cards has failures or is missing.
EID-6002
One of the XC cards is locked.
EID-6003
The OSC termination could not be created.
This ring ID is already assigned.
EID-6004
A system reset cannot be performed while a BLSR ring is
provisioned on the node.
EID-6005
The timing references could not be assigned.
- Only two DS1 or BITS interfaces can be specified.
- DS1 interfaces cannot be retimed and used as a reference.
- BITS-2 is not supported on this platform.
EID-6006
The timing references could not be assigned.
- An NE reference can only be used if the timing mode is LINE.
- A BITS reference can only be used if the timing mode is not
LINE.
- A Line reference can only be used if the timing mode is not
EXTERNAL.
EID-6008
SF BER and SD BER are not provisionable on the protect line
of a protection group.
WID-6009
If autoadjust GFP buffers is disabled, GFP buffers available
must be set to an appropriate value based on the distance
between the circuit endpoints.
WID-6010
If auto detection of credits is disabled, credits available must be
set to a value less than or equal to the number of receive credits
on the connected FC endpoint.
Cisco ONS 15600 SDH Troubleshooting Guide, R8.0
4-38
Chapter 4 Error Messages
Description
Refer to the error message text.
During an RPR circuit creation on an
ML-Series card, the new circuit size and the
existing circuit size must be the same.
The trunk specified is not found.
Refer to the error message.
Refer to the error message.
Refer to the error message text.
Check whether all the cross-connect cards
are installed and working.
Unlock the cross-connect card.
Enter a new ID for the ring.
Remove the MS-SPRing from the node and
continue with the reset procedure.
Refer to the error message text.
Refer to the error message text.
Refer to the error message text.
Refer to the warning message text.
Refer to the warning message text.
July 2010

Advertisement

Table of Contents
loading

Table of Contents