3) Set dial gauge to mounting dummy and make 0 (zero)
adjustment on surface plate.
NOTE:
• When setting dial gauge to mounting dummy, tighten
screw lightly. Be careful not to overtighten it, which will
cause damage to dial gauge.
• With dial gauge set, turn dummy back and force by
hand a couple of times and attain accurate 0 (zero)
adjustment.
• It is desirable that short pointer indicates beyond 2 mm
when long one is at 0 (zero).
Special tool
(A) : 09900-20606
(B): 09926-78320
1. Surface plate
2. Screw
4) Place zero-adjusted mounting dummy and dial gauge set on
pinion mounting dummy and take measurement between
zero position and extended dial gauge measuring tip.
NOTE:
• Repeat turning back and force of dummy and measure
distance as far as top surface of pinion dummy accu-
rately.
• When dial gauge measuring tip extends from 0 (zero)
position, pointer turns counterclockwise.
• Measured value may exceed 1 mm. Therefore, it is also
necessary to know reading of short pointer.
Special tool
(A) : 09900-20606
(B) : 09926-78311
(D) : 09922-76570
(F) : 09926-78311-002
5) Obtain adjusting shim thickness by using measured value by
dial gauge in previous step.
Neces-
Dial gauge
sary shim
=
measured
thickness
value "c"
"e"
DIFFERENTIAL (REAR) 7F-15

Advertisement