Suzuki GRAND VITARA XL-7 Owner's Manual page 48

Hide thumbs Also See for GRAND VITARA XL-7:
Table of Contents

Advertisement

3
5
4
6
1
The initial charging of the A/C system is performed from the high-
pressure side with the engine stopped.
And next, this method must be followed by charging from the low-
pressure side with the engine running.
1) Check to make sure that hoses are routed properly after
evacuating the system.
2) Connect Low-side hose (1) and High side hose (2) of the
manifold gauge set (3) in position. Thus open refrigerant
container valve (4) to purge the charging line.
3) Open the high-pressure side valve (6) and charge refrigerant
to system.
4) After a while, open the low-pressure side valve (5) and close
the high-pressure side valve (6).
WARNING:
Make sure that high pressure-side valve is closed
2
securely.
5) Start engine and keep engine speed at 1500 rpm. Then,
operate air conditioning.
NOTE:
Dual A/C model must be operated rear A/C system, too.
6) Charge A/C system with refrigerant in vapor state. At this
time, refrigerant container should be held upright.
7) When refrigerant container (3) is emptied, the use following
procedure to replace it with a new refrigerant container (3).
a) Close low pressure valve.
b) Replace empty container (3) with a refrigerant container
which has been charged with refrigerant. When using
refrigerant container tap valve (4), use following procedure
for replacement.
i) Retract needle (1) and remove refrigerant container tap
valve (4) by loosening its plate nut (2).
ii) Install previously-removed refrigerant container tap valve
(4) to a new refrigerant container (3).
AIR CONDITIONING (OPTIONAL) 1B-23

Advertisement

Table of Contents
loading