high_alarm - Specify the high threshold value for the temperature alarm.When the operating
parameter rises above this value, the action associated with the alarm is taken.
<voltage> - Enter the high threshold alarm value used here.
low_alarm - Specify the low threshold value for the temperature alarm.When the operating
parameter falls below this value, the action associated with the alarm is taken.
<voltage> - Enter the low threshold alarm value used here.
high_warning - Specify the high threshold for the warning. When the operating parameter
rises above this value, the action associated with the warning is taken.
<voltage> - Enter the high threshold warning value here.
low_warning - Specify the low threshold for the warning. When the operating parameter falls
below this value, the action associated with the warning is taken.
<voltage> - Enter the low threshold warning value here.
bias_current_threshold - Specify the threshold of the optic module's bias current.
high_alarm - Specify the threshold of the optic module's output power.
<milliampere> - Enter the high threshold alarm value used here.
low_alarm - Specify the threshold of optic module's received power.
<milliampere> - Enter the low threshold alarm value used here.
high_warning - Specify the high threshold for the warning. When the operating parameter
rises above this value, the action associated with the warning is taken.
<milliampere> - Enter the high threshold warning value here.
low_warning - Specify the low threshold for the warning. When the operating parameter falls
below this value, the action associated with the warning is taken.
<milliampere> - Enter the low threshold warning value here.
tx_power_threshold - Specify the threshold of the optic module's output power.
high_alarm - Specify the high threshold for the alarm. When the operating parameter rises
above this value, the action associated with the alarm is taken.
<mw_or_dbm> - Enter the high threshold alarm value used here.
low_alarm - Specify the low threshold for the alarm. When the operating parameter falls
below this value, the action associated with the alarm is taken.
<mw_or_dbm> - Enter the low threshold alarm value used here.
high_warning - Specify the high threshold for the warning. When the operating parameter
rises above this value, the action associated with the warning is taken.
<mw_or_dbm> - Enter the high threshold warning value here.
low_warning - Specify the low threshold for the warning. When the operating parameter falls
below this value, the action associated with the warning is taken.
<mw_or_dbm> - Enter the low threshold warning value here.
rx_power_threshold - Specify the threshold of optic module's received power.
high_alarm - Specify the high threshold for the alarm. When the operating parameter rises
above this value, the action associated with the alarm is taken.
<mw_or_dbm> - Enter the high threshold alarm value used here.
low_alarm - Specify the low threshold for the alarm. When the operating parameter falls
below this value, the action associated with the alarm is taken.
<mw_or_dbm> - Enter the low threshold alarm value used here.
high_warning - Specify the high threshold for the warning. When the operating parameter
rises above this value, the action associated with the warning is taken.
<mw_or_dbm> - Enter the high threshold warning value here.
low_warning - Specify the low threshold for the warning. When the operating parameter falls
below this value, the action associated with the warning is taken.
<mw_or_dbm> - Enter the low threshold warning value here.
state - Specify the DDM state to enable or disable. If the state is disabled, no DDM action will
take effect.
enable - Specify to enable the DDM state.
disable - Specify to disable the DDM state.
shutdown - Specify whether or not to shutdown the port when the operating parameter exceeds
the corresponding alarm threshold or warning threshold. The default value is none.
alarm - Shuts down the port when the configured alarm threshold range is exceeded.
warning - Shuts down the port when the configured warning threshold range is exceeded.
none - The port will never shut down regardless if the threshold ranges are exceeded or not.
reload_threshold - Specify the reloading threshold limit. Manually reload the DDM threshold