D-Link DGS-3000 Reference Manual page 120

Hide thumbs Also See for DGS-3000:
Table of Contents

Advertisement

DGS-3000 Series Layer 2 Managed Gigabit Ethernet Switch CLI Reference Guide
DGS-3000-26TC:admin#show autoconfig
Command: show autoconfig
Autoconfig State: Disabled
Timeout
: 50 sec
DGS-3000-26TC:admin#
9-4
config autoconfig timeout
Description
This command is used to configure the timeout value. This timer is used to limit the length of time
in getting configuration settings from the network. When timeout occurs, the auto configuration
operation will be stopped and the local configuration file will be used to configure the system.
Format
config autoconfig timeout <value 1-65535>
Parameters
<value 1-65535> - Enter the timeout length in seconds. The default setting is 50 seconds.
Restrictions
Only Administrator, and Operator level users can issue this command.
Example
To configure auto configuration timeout:
DGS-3000-26TC:admin#config autoconfig timeout 60
Command: config autoconfig timeout 60
Success.
DGS-3000-26TC:admin#