Menus 15 to 17
Parameter
Keypad and
SM-Uni Enc Pl
structure
display
x.49

Lock position feedback

Drive modes
Open-loop, Closed-loop vector, Servo
Bit
SP
Coding
1
Update rate
Background write
If Pr x.49 is set to one, Pr x.04, Pr x.05 and Pr x.06 are not updated. If this parameter is zero, Pr x.04, Pr x.05 and Pr x.06 are updated normally.
x.50

Solutions Module error status

Drive modes
Open-loop, Closed-loop vector, Servo, Regen
Bit
SP
Coding
Range
Open-loop, Closed-loop, Servo, Regen
Update rate
Background write
The error status is provided so that only one Solutions Module error trip is required for each Solutions Module slot. If an error occurs the reason for
the error is written to this parameter and the drive may produce a SLotx.Er trip, where x is the slot number. A value of zero indicates that the module
has not detected an error, a non-zero value indicates that an error has been detected. (See descriptions for each category for the meaning of the
values in this parameter.) When the drive is reset this parameter is cleared for all Solutions Modules.
All modules include a temperature monitoring circuit. If the PCB temperature exceeds 90°C the drive fan is forced to operate at full speed (for a
minimum of 10s). If the temperature falls below 90°C the fan can operate normally again. If the PCB temperature exceeds 100°C the drive is tripped
and the error status is set to 74.
x.51

Option software sub-version

Drive modes
Open-loop, Closed-loop vector, Servo, Regen
Bit
SP
Coding
Range
Open-loop, Closed-loop, Servo, Regen
Update rate
Write on power-up
Most Solutions Modules include a processor with software. The software version is displayed in these parameters in the form Pr x.02 = xx.yy and Pr
x.50 = zz. Where xx specifies a change that affects hardware compatibility, yy specifies a change that affects product documentation, and zz specifies
a change that does not affect the product documentation. When a module is fitted that does not contain software both these parameters appear as
zero.
246
Parameter
Parameter
x.00
description format
FI
DE
Txt VM DP
ND
FI
DE
Txt VM DP
ND
1
0 to 255
FI
DE
Txt VM DP
ND
1
0 to 99
www.controltechniques.com
http://nicontrols.com
Advanced parameter
Macros
descriptions
RA
NC
NV
PT
US RW BU
1
RA
NC
NV
PT
US RW BU
1
1
RA
NC
NV
PT
US RW BU
1
1
Serial comms
Electronic
Performance
protocol
nameplate
PS
PS
1
PS
1