Parameter
Keypad and
Parameter
structure
display
x.00
12.49
Enable position controller during brake release
Drive modes
Closed-loop vector, Servo
Coding
Bit
SP
1
Default
Closed-loop vector, Servo
Update rate
Background read
If this parameter is zero then ramp hold only is applied when the drive is not active and until the end of the post-brake release delay to ensure that the
speed reference remains at zero until the brake has released. If this parameter is set to one the position controller (see menu 13) is also enabled (Pr
13.10 = 1) and the local position reference source is selected (Pr 13.04 = 4(LocAL)) during the period when ramp hold is active. Provided the default,
non-absolute mode, is selected the position controller can help to limit the movement of the motor when the brake is released. When Pr 12.49 is
changed from one to zero Pr 13.04 and Pr 13.10 are automatically set to zero.
Unidrive SP Advanced User Guide
Issue Number: 7
Parameter
Advanced parameter
description format
descriptions
FI
DE
Txt VM DP
ND
0
www.controltechniques.com
http://nicontrols.com
Serial comms
Macros
protocol
RA
NC
NV
PT
US RW BU
1
1
Electronic
Feature look-
Performance
nameplate
up table
PS
Menu 12