Parameter
Keypad and
Menu 7
structure
display
7.15

T8 analog input 3 mode

Drive modes
Open-loop, Closed-loop vector, Servo, Regen
Bit
SP
FI
Coding
Open-loop, Closed-loop vector, Servo,
Range
Regen
Open-loop,
Default
Closed-loop vector, Servo, Regen
Update rate
Background read
The following modes are available for the analog input 3. A current loop loss trip is generated if the input current falls below 3mA. In modes 4 and 5
the analog input level goes to 0.0% if the input current falls below 3mA.
Parameter value
Parameter string
0
1
2
3
4
5
6
7
8
9
7.16

T8 analog input 3 scaling

Drive modes
Open-loop, Closed-loop vector, Servo, Regen
Bit
SP
FI
Coding
Open-loop, Closed-loop vector, Servo,
Range
Regen
Open-loop, Closed-loop vector, Servo,
Default
Regen
Update rate
Background read
7.17

T8 analog input 3 invert

Drive modes
Open-loop, Closed-loop vector, Servo, Regen
Bit
SP
FI
Coding
1
Open-loop, Closed-loop vector, Servo,
Default
Regen
Update rate
Background read
7.18

T8 analog input 3 destination

Drive modes
Open-loop, Closed-loop vector, Servo, Regen
Bit
SP
FI
Coding
Open-loop, Closed-loop vector, Servo,
Range
Regen
Open-loop, Closed-loop vector, Servo,
Default
Regen
Update rate
Read on drive reset
140
Parameter
Parameter
x.00
description format
DE
Txt VM DP
ND
1
0 to 9
8
6
0-20
20-0
4-20.tr
4 -20mA with trip on loss
20-4.tr
20 - 4mA with trip on loss
4-20
4 - 20mA with no trip on loss
20-4
20 - 4mA with no trip on loss
VOLt
th.SC
Thermistor with short circuit detection
th
Thermistor without short circuit detection
th.diSp
Thermistor display only with no trip
DE
Txt
VM
DP
ND
3
0.000 to 4.000
1.000
DE
Txt VM DP
ND
0
DE
Txt VM DP
ND
1
2
Pr 0.00 to Pr 21.51
Pr 0.00
www.controltechniques.com
http://nicontrols.com
Advanced parameter
Macros
descriptions
RA
NC
NV
PT
US RW BU
1
1
Mode
0 - 20mA
20 - 0mA
Voltage mode
RA
NC
NV
PT
US RW BU
1
1
RA
NC
NV
PT
US RW BU
1
1
RA
NC
NV
PT
US RW BU
1
1
1
Serial comms
Electronic
Performance
protocol
nameplate
PS
1
Comments
Trip if I < 3mA
Trip if I < 3mA
0.0% if I < 4mA
TH trip if R > 3k3
TH reset if R < 1k8
THS trip if R < 50R
TH trip if R > 3k3
TH reset if R < 1k8
PS
1
PS
PS
1
Unidrive SP Advanced User Guide
Issue Number: 7
Feature look-
up table

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the unidrive sp and is the answer not in the manual?

Questions and answers

Table of Contents

Save PDF