Parameter
Keypad and
Menu 10
structure
display
10.36
Hold drive healthy until last attempt
Drive modes
Open-loop, Closed-loop vector, Servo, Regen
Bit
SP
Coding
1
Open-loop, Closed-loop vector, Servo,
Default
Regen
Update rate
Background read
If this parameter is 0 then Pr 10.01 (Drive healthy) is cleared every time the drive trips regardless of any auto-reset that may occur. When this
parameter is set the 'Drive healthy' indication is not cleared on a trip if an auto-reset is going to occur.
10.37
Action on trip detection
Drive modes
Open-loop, Closed-loop vector, Servo, Regen
Bit
SP
Coding
Open-loop, Closed-loop vector, Servo,
Range
Regen
Open-loop, Closed-loop vector, Servo,
Default
Regen
Update rate
Background read
Braking IGBT trip mode
0
Trip
1
Trip
2
Disable
3
Disable
For details of braking IGBT trip mode see Pr 10.31 on page 176.
If stop on low priority trips is selected the drive will stop before tripping except in Regen mode where the drive trips immediately. Low priority trips are:
th, ths, Old1, cL2, cL3, SCL.
178
Parameter
Parameter
x.00
description format
FI
DE
Txt VM DP
ND
0
FI
DE
Txt VM DP
ND
0 to 3
0
Stop on low priority trips
www.controltechniques.com
http://nicontrols.com
Advanced parameter
Macros
descriptions
RA NC NV
PT
US RW BU
1
1
RA NC NV
PT
US RW BU
1
1
No
Yes
No
Yes
Serial comms
Electronic
Performance
protocol
nameplate
PS
PS
1
Unidrive SP Advanced User Guide
Issue Number: 7
Feature look-
up table
Need help?
Do you have a question about the unidrive sp and is the answer not in the manual?