Control Techniques unidrive sp Advanced User's Manual page 149

Universal variable speed ac drive for induction and servo motors
Hide thumbs Also See for unidrive sp:
Table of Contents

Advertisement

Parameter
Keypad and
Menu 8
structure
display
Open-loop, closed-loop vector and servo
Table 5-4
Terminal + type
T24 input / output 1
T25 input / output 2
T26 input / output 3
T27 input 4
T28 input 5
T29 input 6
T41 / 42 Relay
T22 24V output
T31 Enable
Regen
Table 5-5
Terminal + type
T24 input / output 1
T25 input / output 2
T26 input / output 3
T27 input 4
T28 input 5
T29 input 6
T41 / 42 Relay
T22 24V output
T31 Enable
8.01
T24 digital I/O 1 state
8.02
T25 digital I/O 2 state
8.03
T26 digital I/O 3 state
8.04
T27 digital input 4 state
8.05
T28 digital input 5 state
8.06
T29 digital input 6 state
8.07
Relay status
8.08
T22 24V output state
8.09
Drive enable indicator
Drive modes
Open-loop, Closed-loop vector, Servo, Regen
Bit
SP
Coding
1
Update rate
4ms write
8.10
Drive enable mode select
Drive modes
Open-loop, Closed-loop vector, Servo, Regen
Coding
Bit
SP
1
Open-loop, Closed-loop vector, Servo,
Default
Regen
Update rate
Background read
Unidrive SP has a dedicated hardware enable input which always controls Pr 6.29. If the enable is inactive the IGBT firing signals are turned off
without software intervention. As default (Pr 8.10 = 0) the drive is in the inhibit mode when the enable is inactive. Setting this parameter to one causes
148
Parameter
Parameter
x.00
description format
I/O state
Invert
Pr
Pr
Default
Pr 8.01
Pr 8.11
Pr 8.02
Pr 8.12
Pr 8.03
Pr 8.13
Pr 8.04
Pr 8.14
Pr 8.05
Pr 8.15
Pr 8.06
Pr 8.16
Pr 8.07
Pr 8.17
Pr 8.08
Pr 8.18
Pr 8.09
I/O state
Invert
Pr
Pr
Default
Pr 8.01
Pr 8.11
Pr 8.02
Pr 8.12
Pr 8.03
Pr 8.13
Pr 8.04
Pr 8.14
Pr 8.05
Pr 8.15
Pr 8.06
Pr 8.16
Pr 8.07
Pr 8.17
Pr 8.08
Pr 8.18
Pr 8.09
FI
DE
Txt VM DP
ND
1
FI
DE
Txt VM DP
ND
OFF (0)
www.controltechniques.com
http://nicontrols.com
Advanced parameter
Macros
descriptions
Source / destination
Pr
0
Pr 8.21
Pr 10.03 - Zero speed
0
Pr 8.22
Pr 10.33 - Drive reset
0
Pr 8.23
Pr 6.30 - Run forward
0
Pr 8.24
Pr 6.32 - Run reverse
0
Pr 8.25
Pr 1.41 – Local/remote
0
Pr 8.26
0
Pr 8.27
Pr 10.01 – Drive healthy
1
Pr 8.28
Source / destination
Pr
0
Pr 8.21
Pr 3.09 - Enble motor drive
0
Pr 8.22
Pr 3.08 - Contactor closed
0
Pr 8.23
Pr 10.01 – Drive healthy
0
Pr 8.24
Pr 0.00 - Not used
0
Pr 8.25
Pr 0.00 - Not used
0
Pr 8.26
Pr 0.00 - Not used
0
Pr 8.27
Pr 3.07 – Close contactor
1
Pr 8.28
Pr 0.00 - Not used
RA NC NV
PT
US RW BU
1
1
RA NC NV
PT
US RW BU
1
Serial comms
Electronic
Performance
protocol
nameplate
Default
Pr 8.31
Pr 8.32
Pr 8.33
Pr 6.31 – Jog
Pr 0.00
Default
Pr 8.31
Pr 8.32
Pr 8.33
PS
PS
1
Unidrive SP Advanced User Guide
Feature look-
up table
Output select
Pr
Default
1
0
0
Output select
Pr
Default
1
0
1
Issue Number: 7

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the unidrive sp and is the answer not in the manual?

Questions and answers

Table of Contents

Save PDF