Flash Non-Service Affecting Alarms - HP VMA Series Installation And Service Manual

Memory array
Hide thumbs Also See for VMA Series:
Table of Contents

Advertisement

HP-AM456-9002A Rev 01
Fan Running Too Slowly Alarm
The Fan Running Too Slowly alarm indicates that the fan specified is present but
is spinning slowly. The speed of the fan is given in rpm.
Fan Tray Removed Alarm
The Fan Tray Removed alarm indicates that the specified fan tray has been
removed after the system has booted. The alarm specifies whether the top (
or bottom (
) fan tray has been removed.
2
To clear the alarm, replace the fan tray in the system.
Fan Running Too Slowly Alarm
The Fan Running Too Slowly alarm indicates that the specified fan is running at
a much lower speed than it should. The alarm specifies the top (
fan tray and the fan within that fan tray:
To clear the alarm, replace the fan tray in the system.

Flash Non-Service Affecting Alarms

There are five non-service affecting flash alarms.
Flash CPL IRQs on VIMM Alarm
Flash Format Failed on VIMM Alarm
Flash Sequence Number Mismatch Alarm
Preparing Flash on VIMM Alarm
VIMM Flash Format In Progress Alarm
Flash CPL IRQs on VIMM Alarm
The Flash CPL IRQs on VIMM alarm indicates that an error has been detected
by the Flash VIMM Control Plane.
This is a fatal error on the VIMM and it must be taken out-of-service, using the
set chassis board 0 slot XX vimm admin-state down
returned.
Flash Format Failed on VIMM Alarm
The Flash Format Failed on VIMM alarm indicates that the format operation on
the specified VIMM failed. The VIMM will be taken out-of-service.
VMA-series Memory Array Installation and Service Guide
Non-Service Affecting Alarms
,
, or
left
center
right
on page 199
on page 199
on page 200
on page 200
on page 200
)
1
) or bottom (
)
1
2
.
command and
199