Chapter 6 - Servicing the Array
Replacing the AC Power Supplies
PORT 1
Figure 6.2 Replacing an AC Power Supply
112
The redundant AC power supplies can be hot-swapped at any time if one fails
during operation of the Memory Array.
To replace an AC power supply:
At the rear of theMemory Array, disconnect the AC power cord from the
1.
system and the wall outlet.
Remove the module by pushing on the green tab at the right of the power
2.
supply faceplate and pulling the power supply firmly by the handle over the
fan, as illustrated in the figure below.
Orient the power supply, as shown in the figure above, with the faceplate
3.
towards the installer and the AC cord receptacle to the right.
Place the new power supply in the chassis and push firmly until the green
4.
tab clicks into place.