HP-AM456-9002A Rev 01
Before removing the VIMM, change the administrative state to
WARNING!
down. If you fail to do so, the VIMM, the slot that it is in, or the main board may
experience permanent electrical damage and cease to operate.
If a VIMM is an active member of a RAID group and its administrative state is set
to down, a RAID group rebuild begins. If the VIMM is in a RAID group that cannot
survive with the VIMM being taken out of the group, then data loss will occur.

show

Displays configuration information for the VIMM in the specified slot.
Syntax
show
Example
To display the configuration information for the flash VIMM in slot 56, at the
VIMM context prompt, type:
show
The command displays information similar to the following:
chassis board 0 slot 56 vimm> show
admin-state
oper-state
vimm-state
raid-group
vimm-type
mem-type
raw-capacity
raw-capacity-bytes
fmt-capacity
fmt-capacity-bytes
part-number
serial-number
mfg-date
fw-date
fw-version
sw-date
sw-version
is-programmed
id-assigned
VMA-series Memory Array Installation and Service Guide
up
up
active
0
FLASH
SLC-NAND
68.7GB (64GiB)
68,719,476,736
45.1GB (42GiB)
45,097,156,608
1000159A-B-P4
18094R00000003
20090422
Thu Feb 11 17:54:00 2010
0x39df
Fri Feb 12 00:07:00 2010
0x39dd
true
true