HP-AM456-9002A Rev 01
•
Equipment Service-Affecting Alarms
•
Flash Service-Affecting Alarms
•
Port Service-Affecting Alarms
•
Power Service-Affecting Alarms
•
RAID Service-Affecting Alarms
•
System Service-Affecting Alarms
•
Temperature Service-Affecting Alarms
•
VIMM Service-Affecting Alarms
Equipment Service-Affecting Alarms
There are two service affecting equipment alarms.
•
Booting Suspended, Fan-tray Missing Alarm
•
Booting Suspended, Fans Missing Alarm
Booting Suspended, Fan-tray Missing Alarm
The Booting Suspended, Fan-tray Missing alarm indicates that one or more fan
trays are missing on the Memory Array.
To clear the alarm, insert the missing fan tray(s).
Booting Suspended, Fans Missing Alarm
The Booting Suspended, Fans Missing alarm indicates that booting has been
suspended because an insufficient number of fans were detected. The alarm
indicates the number of fans missing.
Flash Service-Affecting Alarms
There are two service affecting flash alarms.
•
Fatal Flash Error, <Hex-Value> Alarm
•
Unformatted System Alarm
Fatal Flash Error, <Hex-Value> Alarm
The Fatal Flash Error, <Hex-Value> alarm indicates that a flash-based VIMM has
encountered a fatal error and is no longer operational. The alarm indicates the
non-functional VIMM number by the hex value displayed in the alarm. The system
must shut down because the non-functional VIMM has made the current VIMM
configuration invalid.
VMA-series Memory Array Installation and Service Guide
on page 191
on page 191
on page 192
on page 192
on page 193
on page 194
on page 195
on page 196
on page 191
on page 191
on page 191
on page 192
Service-Affecting Alarms
191