Chapter 5 - Operating the System via the CLI

Displaying and Setting Hardware Information

92
Display hardware information for the Memory Array, including:
Fan tray status
Which slots are populated with VIMMs
Individual VIMM information
Test slots
System LEDs

Displaying VIMM Configuration Information

Display the VIMM configuration information at the
To display the VIMM configuration information:
Log into the Memory Array.
1.
Navigate to the desired
2.
context chassis board 0 slot <
Where:
n
Specifies the VIMM slot number to move to. Valid values are in
the range of 0–83, inclusive.
At the context prompt, type:
3.
show vimm
This command displays text similar to the following:
chassis board 0 slot 56> show vimm
admin-state
oper-state
vimm-state
raid-group
vimm-type
mem-type
raw-capacity
raw-capacity-bytes
fmt-capacity
fmt-capacity-bytes
part-number
serial-number
mfg-date
fw-date
fw-version
VMA-series Memory Array Installation and Service Guide
Slot
context level. At the root prompt, type:
n
>
up
up
active
0
FLASH
SLC-NAND
68.7GB (64GiB)
68,719,476,736
45.1GB (42GiB)
45,097,156,608
1000159A-B-P4
18094R00000003
20090422
Thu Feb 11 17:54:00 2010
0x39df
Slot
context level.
HP-AM456-9002A Rev 01