Displaying The Spare Vimm Information - HP VMA Series Installation And Service Manual

Memory array
Hide thumbs Also See for VMA Series:
Table of Contents

Advertisement

HP-AM456-9002A Rev 01
Indicates the state of the VIMM in the 5-VIMM RAID
state
group. Valid values are:
• data—VIMM is being used for data, either user data or parity
• REBUILDING—VIMM is currently being rebuilt by the RAID
• FAULT—A fault has occurred for this VIMM. If a spare is

Displaying the Spare VIMM Information

Using the CLI, display the ID numbers of the VIMMs that are designated as
spares for use with the RAID groups.
Log into the Memory Array.
1.
RAID
Navigate to the
2.
context raid
RAID
At the
context prompt, type:
3.
show spare-ids
The command displays information similar to the following:
raid> show spare-ids
spare-ids
VMA-series Memory Array Installation and Service Guide
Displaying and Setting System Information
data.
engine to recover from a prior failure.
available, a rebuild occurs for this virtual VIMM.
context level. At the root prompt, type:
30,31,32,52
91

Advertisement

Table of Contents
loading

Table of Contents