Cabling The Mgc; Cabling The Cp Pm Call Server - Nortel 1000E Upgrade

Option 11c chassis upgrade
Table of Contents

Advertisement

Cabling the MGC

The existing 3-port SDI cable (NTBK48AA) is reused. It connects to the SDI
port on the Chassis. Figure 9 on
CT ports are reserved for the CP PM card only. The CE connects to the ELAN
port of the call server, while the CT connects to the TLAN port of the call
server. The 1E and 2T ports must be attached to the layer 2 switch.
MGC Ethernet Capabilities
An MGC features six Ethernet interfaces set to autonegotiate by default: four
on the faceplate (see Figure 9 on
page
various ethernet connections.
Figure 9
MGC faceplate
CE: ELAN
Dedicated for
CP PM
CT: TLAN
Dedicated for
CP PM-SS

Cabling the CP PM call server

In a typical configuration, the com (SDI) port of the CP PM call server is
routed through the backplane of the shelf to the 50-pin Amphinol connector
Communication Server 1000E Upgrade
76, Figure 11 on
page
2T: TLAN
Dual homed with
Backplane T
Option 11C Chassis to Communication Server 1000E
Installing CS 1000E hardware
page 75
shows the front of MGC. The CE and
page
75), and two on the back. Figure 10 on
77, and Figure 12 on
1E: ELAN
Dual homed with
Backplane E
Page 75 of 228
page 78
illustrate the

Advertisement

Table of Contents
loading

Table of Contents