252 MG 1000B software installation
Installing the MGC card
Step
1
You must ensure that all dongles (for both MGC and CP PM cards) are correctly
identified.
Please DESTROY or RETURN the SSC dongle to your local Nortel
Repairs/Returns center.
For the MGC card and the CP PM call server, you must use the dongles provided
in the software kit. Chassis Expander dongles may be disposed of, as they are
no longer needed.
2

Installing the CP PM card

The following procedure describes how to install the CP PM card in a
Chassis.
Ensure that all DIP switches are set correctly. DIP switches determine
whether the CP PM boots from a hard drive or compact flash.
Installing the CP PM card
Step
1
2
3
4
Copyright © 2007, Nortel Networks
.
Action
Insert the MGC into Slot 0 of the Chassis.
The existing 3-port SDI cable (NTBK48AA) is reused. It connects
to the SDI port on the Chassis.
Action
Ensure that the security dongle (the one that comes as part of the
software kit) is inserted on the CP PM call processor.
Slide the CP PM call processor into Slot 1 (or higher) of the Chassis.
Lock the card into the faceplate latches.
Attach the SDI cable. The 50-pin Amphinol connects to the back
of the CP PM call server.
Nortel Communication Server 1000
Branch Office Installation and Commissioning
NN43001-314 01.02 Standard
Release 5.0 20 June 2007
ATTENTION
—End—