Canon imageRUNNER ADVANCE 9070 PRO series Service Manual Digest page 76

Hide thumbs Also See for imageRUNNER ADVANCE 9070 PRO series:
Table of Contents

Advertisement

E
Detailed
Occurance
Items
code
code
area
E025 -0102
-05
Title
Description
of detection
Measures
E025 -0110
-05
Title
3
Description
of detection
Measures
3-50
Description
Block supply timeout (Y) error
The toner supply screw rotation sensor cannot detect
rotation of the screw.
1. Check the connection between the hopper/stirring
supply motor (M6) and the hopper driver PCB.
Motor side: J7100, J8106 PCB side: J1340
2. Check the connection between the toner feed screw
rotation sensor (PS9) and the hopper driver PCB.
Sensor side: J7418, J8106 PCB side: J1340
3. Replace the hopper/stirring supply motor.
4. Clean and replace the toner feed screw rotation
sensor.
5. Replace the toner supply pipe unit.
6. Replace the hopper unit.
CAUTION:
Remedies 5 and 6 are taken when the motor is
overloaded due to toner adhesion in the unit or gear
interlocking failure, etc. Since it is difficult to identify the
cause, it is recommended to replace the unit.
Toner container sealing/release holder shift cam HP
sensor timeout (Y) error
HP sensor of release holder shift cam cannot detect
within specified period of time.
1. Check the connection of the toner container drive
motor (M10) harness. (Check whether the wire is
not caught by parts.) Check the connection with the
hopper driver PCB.
Motor side: J7104 PCB side: J1370
2. Check the connection between the release holder shift
cam HP sensor (PS8) and the hopper driver PCB.
Sensor side: J7123, J8106 PCB side: J1340
3. Replace the toner container drive motor.
4. Clean and replace the release holder shift cam HP
sensor.
5. Replace the hopper unit.
CAUTION:
As for Remedy 5, since it is difficult to identify the cause,
it is recommended to replace the unit.
NOTE: After performing the above remedy work, go
through the following to clear the error: COPIER>
FUNCTION> CLEAR> ERR
E
Detailed
Occurance
Items
code
code
area
E025 -0120
-05
Title
Toner container/toner container inserting inlet phase (Y)
error
Description
When the power was turned on, it was detected that the
of detection
toner container cap was opened (the release holder shift
cam phase sensor was protected against light) AND the
toner container inserting inlet cover was opened (the
toner container inserting inlet cover open/close sensor
was transmissive).
Measures
1. Close the toner container inserting inlet cover and turn
2. Check the connection between the toner container
3. Check the connection between the release holder shift
4. Replace the toner container inserting inlet cover open/
Description
OFF/ON the power.
inserting inlet cover open/close sensor (PS10) and
the hopper driver PCB. (Connection of the connector,
Breaking, Wire caught by parts)
Sensor side: J7122, J8115 PCB side: J1360
cam phase sensor (PS81) and the hopper driver PCB.
(Connection of the connector, Breaking, Wire caught
by parts)
Sensor side: J7153 PCB side: J1390
close sensor.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents