Canon imageRUNNER ADVANCE 9070 PRO series Service Manual Digest page 167

Hide thumbs Also See for imageRUNNER ADVANCE 9070 PRO series:
Table of Contents

Advertisement

E
Detailed
Occurance
Items
code
code
area
E713 -0001
-05
Title
Finisher communication error
Description
Communication failed between the finisher and the host
of detection
machine.
Measures
1. Check the cable connection.
2. Replace the finisher controller circuit PCB.
3. Replace the DC controller circuit PCB.
E717 -0001
-00
Title
Communication with the NE controller is abnormal
Description
Error in the NE controller start
of detection
When the NE controller which should have been
connected is not connected before the power off at power
supply time to turn on
Measures
Recover with service mode COPIER> FUNCTION>
CLEAR> ERR after cable check
E717 -0002
-00
Title
Communication with the NE controller is abnormal
Description
IPC error in the NE controller operation
of detection
In the case of the errors that disconnection of IPC, or IPC
communication is unrecoverable.
Measures
Recover with service mode COPIER> FUNCTION>
CLEAR> ERR after cable check
E719 -0001
-00
Title
Coin vendor failure
Description
Error in starting of the CoinVendor
of detection
- The Coin Vendor, which should have been connected
before the power was turned OFF, is not connected when
the power is turned ON.
Measures
Check the connection between charging management
equipment and machine, and check that the Cable is not
open-circuit.
Clear the error while the charging management
equipment is connected to operate and when switching to
the operation without charging management equipment.
(To prevent the misuse by removing the charging
management equipment, this error code is displayed.)
Description
E
Detailed
Occurance
Items
code
code
area
E719 -0002
-00
Title
Coin vendor failure
Description
Error in IPC when CoinVendor is running.
of detection
- In the case of disconnection of IPC or an error in which
IPC communication failed to be recovered.
- When disconnection of the pickup delivery signal is
detected.
- When illegal connection is detected (short-circuit with
Tx and Rx of IPC)
Measures
Check the connection between charging management
equipment and machine, and check that the Cable is not
open-circuit.
Clear the error while the charging management
equipment is connected to operate and when switching to
the operation without charging management equipment.
(To prevent the misuse by removing the charging
management equipment, this error code is displayed.)
E719 -0003
-00
Title
Coin vendor failure
Description
- In the case of communication error with the coin vendor
of detection
while obtaining the unit price at start-up.
Measures
Check the connection between charging management
equipment and machine, and check that the Cable is not
open-circuit.
Clear the error while the charging management
equipment is connected to operate and when switching to
the operation without charging management equipment.
(To prevent the misuse by removing the charging
management equipment, this error code is displayed.)
E719 -0011
-00
Title
Error in the card reader startup
Description
Error in starting of NewCardReader
of detection
- NewCardReader, which should have been connected
before the power was turned OFF, is not connected when
the power is turned ON.
Measures
Check the connection between charging management
equipment and machine, and check that the Cable is not
open-circuit.
Clear the error while the charging management
equipment is connected to operate and when switching to
the operation without charging management equipment.
(To prevent the misuse by removing the charging
management equipment, this error code is displayed.)
Description
3
3-141