E
Detailed
Occurance
Items
code
code
area
E004 -0204
-05
Title
Description
of detection
Measures
E004 -0205
-05
Title
Description
of detection
Measures
3
E004 -0301
-05
Title
Description
of detection
Measures
3-12
Description
Pressure belt temperature difference error
Difference of detected temperature between pressure
sub thermistor 2 (THM4) and pressure sub thermistor 1
(THM3) is bigger than the rated value.
1. The connectors of the pressure sub thermistor (THM3,
4) are physically removed (the cable is caught, or
disconnected) -> replace the thermistor or the presure
stay
2. Soiled, improper location of, or faulty pressure sub
thermistor -> clean the thermistor or replace it
3. Faulty drawer connector is a possible cause -> clean
the drawer connector or replace the fixing drawer
cable
4. Replace the DC controller PCB
Thermistor temperature difference error
Difference of detected temperature between thermistors
is bigger than the specified value.
1. The connectors of the fixing main/sub thermistor
(THM1-1 to 3) are physically removed (the cable is
caught, or disconnected) -> replace the fixing belt unit
2. Check the rotation of the fixing motor (the connector
is physically removed or disconnected) -> replace the
fixing motor or the harness
3. The connectors of the pressure sub thermistor (THM2,
3, 4) are physically removed (the cable is caught, or
disconnected) -> replace the thermistor or the presure
stay
4. Disconnection, soiled, improper location of, or faulty
pressure sub thermistor -> clean the thermistor or
replace it
5. Faulty drawer connector -> clean the drawer connector
or replace the fixing drawer cable
6. Replace the DC controller PCB
IH overcurrent detection error
Detected an overcurrent on IH power supply board.
1. Faulty fixing belt unit -> replace the fixing belt unit
2. Faulty fixing IH unit -> replace the fixing IH unit
3. Faulty IH power PCB -> replace the IH power PCB
E
Detailed
Occurance
Items
code
code
area
E004 -0401
-05
Title
12V failure error
Description
Detected abnormality on the 12V power supply line.
of detection
Measures
1. Check the fixing belt -> if it is damaged, replace the
2. Check the connection of the fixing fuse PCB ->
3. Check the connection of the fixing thermoswitch (TP2)
4. Relay PCB replacement
5. DC controller replacement
6. IH power supply replacement
NOTE: After performing the above remedy work, go
through the following to clear the error: COPIER>
FUNCTION> CLEAR> ERR
E004 -0501
-05
Title
Fixing main thermistor, a connection error (circuit failure)
of fixing subthermistor 1/2
Description
Connection sensing signal of fixing main thermistor and
of detection
sub thermistor 1/2 is not detected
Measures
1. Check the connection of the connector on the fixing
2. Faulty drawer connector -> clean the drawer or
E004 -0502
-05
Title
Pressure sub thermistor 1/2 connection error (circuit
abnormality)
Description
sub thermistor 1/2 connection sensing signal is not
of detection
detected
Measures
1. Check the connection of the connector on the
2. Faulty drawer connector -> clean the drawer or
Description
fixing belt unit
replace the fuse PCB
(thermoswitch is OFF, or the cable is disconnected) ->
replace the fixing belt unit
belt unit -> if it is disconnected, replace it
replace the fixing drawer cable
pressure thermistor -> if it is disconnected, replace the
pressure stay
replace the fixing drawer cable

Hide quick links: