COPIER> DISPLAY> HT-C
SUM-A-Y
Dis ARCDAT screen A Y-color ctrl differ
Lv.2 Details
To display Y-patch control difference of screen A in ARCDAT control.
When hue variation occurs and the displayed value is not in the
tolerable range, execute the auto gradation adjustment (reset target
value). Check the Patch Sensor or replace the developer if not
corrected.
Use case
When hue variation occurs
Caution
Take necessary action in accordance with the instructions from the
Quality Support Division.
Display/adj/set range
-1023 to 1023
Default value
0
Supplement/memo
Screen A: High screen ruling screen
SUM-A-M
Dis ARCDAT screen A M-color ctrl differ
Lv.2 Details
To display M-patch control difference of screen A in ARCDAT control.
When hue variation occurs and the displayed value is not in the
tolerable range, execute the auto gradation adjustment (reset target
value). Check the Patch Sensor or replace the developer if not
corrected.
Use case
When hue variation occurs
Caution
Take necessary action in accordance with the instructions from the
Quality Support Division.
Display/adj/set range
-1023 to 1023
Default value
0
Supplement/memo
Screen A: High screen ruling screen
SUM-A-C
Dis ARCDAT screen A C-color ctrl differ
Lv.2 Details
To display C-patch control difference of screen A in ARCDAT control.
When hue variation occurs and the displayed value is not in the
5
tolerable range, execute the auto gradation adjustment (reset target
value). Check the Patch Sensor or replace the developer if not
corrected.
Use case
When hue variation occurs
Caution
Take necessary action in accordance with the instructions from the
Quality Support Division.
Display/adj/set range
-1023 to 1023
Default value
0
Supplement/memo
Screen A: High screen ruling screen
5-84
COPIER> DISPLAY> HT-C
SUM-A-K
Dis ARCDAT screen A Bk-color ctrl differ
Lv.2 Details
To display Bk-patch control difference of screen A in ARCDAT
control.
When hue variation occurs and the displayed value is not in the
tolerable range, execute the auto gradation adjustment (reset target
value). Check the Patch Sensor or replace the developer if not
corrected.
Use case
When hue variation occurs
Caution
Take necessary action in accordance with the instructions from the
Quality Support Division.
Display/adj/set range
-1023 to 1023
Default value
0
Supplement/memo
Screen A: High screen ruling screen
SUM-B-Y
Dis ARCDAT screen B Y-color ctrl differ
Lv.2 Details
To display Y-patch control difference of screen B in ARCDAT control.
When hue variation occurs and the displayed value is not in the
tolerable range, execute the auto gradation adjustment (reset target
value). Check the Patch Sensor or replace the developer if not
corrected.
Use case
When hue variation occurs
Caution
Take necessary action in accordance with the instructions from the
Quality Support Division.
Display/adj/set range
-1023 to 1023
Default value
0
Supplement/memo
Screen B: Low screen ruling screen
SUM-B-M
Dis ARCDAT screen B M-color ctrl differ
Lv.2 Details
To display M-patch control difference of screen B in ARCDAT control.
When hue variation occurs and the displayed value is not in the
tolerable range, execute the auto gradation adjustment (reset target
value). Check the Patch Sensor or replace the developer if not
corrected.
Use case
When hue variation occurs
Caution
Take necessary action in accordance with the instructions from the
Quality Support Division.
Display/adj/set range
-1023 to 1023
Default value
0
Supplement/memo
Screen B: Low screen ruling screen