E020 -0134
-05
Title
Initial installation patch (Y) density upper limit error
Description
When executing developing assembly initial installation
of detection
mode (COPIER> FUNCTION> INSTALL> INISET-Y), the
ATR patch output (SigD) is more than 970.
Measures
• When the value of COPIER> DISPLAY> DENS>
P-LED-DA is large (153(D) or more) and the value of
P-SENS-P is small, there is a high possibility that dirt is
applied to the patch sensor.
• This occurs only at a regular timing. When the value
of COPIER> DISPLAY> DENS> DENS-S-x is small
(2 digits), there is a high possibility that breaking
occurred.
1. Check whether the developing assembly and the drum
unit are properly installed.
2. Clean the patch sensor.
3. Check the connection between the patch sensor and
the DC controller interface PCB. (Connector, Shorting)
Sensor side: J7412, J8035 PCB side: J1242
4. Check open/close operation of the patch shutter.
5. Clean or replace the ITB.
6. Replace the patch sensor unit.
7. Replace the developing assembly.
Description
• Check whether the ITB belt is dirty or not. If it
is dirty, perform cleaning with the service mode
(COPIER> FUNCTION> CLEANING> TBLT-
CLN).
• If it is assumed that this error occurred due to
scratches on the ITB, replace the ITB.
E
Detailed
Occurance
Items
code
code
area
E020 -0136
-05
Title
Initial installation patch (Y) sampling error
Description
When executing developing assembly initial installation
of detection
mode (COPIER> FUNCTION> INSTALL> INISET-Y), the
variation before average patch P wave light intensity is
more than 100.
Measures
• When the value of COPIER> DISPLAY> DENS>
P-LED-DA is large (153(D) or more) and the value of
P-SENS-P is small, there is a high possibility that dirt is
applied to the patch sensor.
• This occurs only at a regular timing. When the value
of COPIER> DISPLAY> DENS> DENS-S-x is small
(2 digits), there is a high possibility that breaking
occurred.
1. Check whether the developing assembly and the drum
unit are properly installed.
2. Clean the patch sensor.
3. Check the connection between the patch sensor and
the DC controller interface PCB. (Connector, Shorting)
Sensor side: J7412, J8035 PCB side: J1242
4. Check open/close operation of the patch shutter.
5. Clean or replace the ITB.
6. Replace the patch sensor unit.
7. Replace the developing assembly.
Description
• Check whether the ITB belt is dirty or not. If it
is dirty, perform cleaning with the service mode
(COPIER> FUNCTION> CLEANING> TBLT-
CLN).
• If it is assumed that this error occurred due to
scratches on the ITB, replace the ITB.
3
3-31