Canon imageRUNNER ADVANCE 9070 PRO series Service Manual Digest page 60

Hide thumbs Also See for imageRUNNER ADVANCE 9070 PRO series:
Table of Contents

Advertisement

E
Detailed
Occurance
Items
code
code
area
E020 -0224
-05
Title
Description
of detection
Measures
3
3-34
Description
Initial installation patch (M) density lower limit error
When executing the developing assembly initial
installation mode (COPIER> FUNCTION> INSTALL>
INISET-M), the ATR patch detection value (SigD) is less
than 79.
• When the value of COPIER> DISPLAY> DENS>
P-LED-DA is large (153(D) or more) and the value of
P-SENS-P is small, there is a high possibility that dirt is
applied to the patch sensor.
• This occurs only at a regular timing. When the value
of COPIER> DISPLAY> DENS> DENS-S-x is small
(2 digits), there is a high possibility that breaking
occurred.
1. Check whether the developing assembly and the drum
unit are properly installed.
2. Clean the patch sensor.
3. Check the connection between the patch sensor and
the DC controller interface PCB. (Connector, Breaking
(shorting))
Sensor side: J7412, J8035 PCB side: J1242
4. Check open/close operation of the patch shutter.
5. Clean or replace the ITB.
• Check whether the ITB belt is dirty or not. If it
is dirty, perform cleaning with the service mode
(COPIER> FUNCTION> CLEANING> TBLT-
CLN).
• If it is assumed that this error occurred due to
scratches on the ITB, replace the ITB.
6. Replace the patch sensor unit.
7. Replace the developing assembly.
E
Detailed
Occurance
Items
code
code
area
E020 -0230
-05
Title
Initial installation toner density sensor (M) output upper
limit error
Description
When executing developing assembly initial installation
of detection
mode (COPIER> FUNCTION> INSTALL> INISET-M),
the output level does not reach 128 even when control
voltage of the toner density sensor became less than 55.
Measures
1. Check the connection between the toner density sensor
and the DC controller interface PCB. (Connector,
Shorting)
<Y> sensor side: J7133, J8028, J8087 PCB side:
J1240, J8085
<M> sensor side: J7134, J8029, J8088 PCB side:
J1240, J8085
<C> sensor side: J7135, J8030, J8089 PCB side:
J1240, J8086
<Bk> sensor side: J7146, J8015, J8117 PCB side:
J1240, J8086
2. Check whether disconnection or shorting of the toner
density sensor occurs or not.
3. Replace the developing assembly.
Description

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents