Canon imageRUNNER ADVANCE 9070 PRO series Service Manual Digest page 421

Hide thumbs Also See for imageRUNNER ADVANCE 9070 PRO series:
Table of Contents

Advertisement

COPIER> ADJUST> CCD
MTF-S2
MTF value 2 setting: vert scan [Back]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Enter the value of service label on the Reader.
Use case
When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
20 to 85
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
MTF-S3
MTF value 3 setting: vert scan [Back]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Enter the value of service label on the Reader.
Use case
When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
20 to 85
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
MTF-S4
MTF value 4 setting: vert scan [Back]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Enter the value of service label on the Reader.
Use case
When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
20 to 85
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
MTF-S5
MTF value 5 setting: vert scan [Back]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Enter the value of service label on the Reader.
Use case
When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
20 to 85
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
MTF-S6
MTF value 6 setting: vert scan [Back]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Enter the value of service label on the Reader.
Use case
When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
20 to 85
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
COPIER> ADJUST> CCD
MTF-S7
MTF value 7 setting: vert scan [Back]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Enter the value of service label on the Reader.
Use case
When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
20 to 85
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
MTF-S8
MTF value 8 setting: vert scan [Back]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Enter the value of service label on the Reader.
Use case
When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
20 to 85
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
MTF-S9
MTF value 9 setting: vert scan [Back]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Enter the value of service label on the Reader.
Use case
When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
20 to 85
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
DFCH-R2
Complex chart No.2 data (R) [Back side]
Lv.1 Details
To derive the front/back side linearity, set the Red data (for paper
back) of No.2 image in DADF complex chart.
Enter the value of service label on the Reader.
Use case
When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
1 to 2550
Default value
2000
Related service mode
COPIER> ADJUST> CCD> DFCH-R10, DFCH-B2, DFCH-B10,
DFCH-G2, DFCH-G10
COPIER> FUNCTION> CCD> DF-LNR
5
5-193