COPIER> OPTION> IMG-FIX
TMP-ST2
Adjustment of standby 2 temperature
Lv.1 Details
To adjust the standby 2 fixing control temperature.
Set a positive value when a fixing failure occurs first time for the day,
and set a negative value when a control temperature cooling wait
time is shorten. (Note the fixing failure.)
Use case
• When a fixing failure occurs first time for the day
• When a control temperature cooling wait time is shorten
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
When -3 or less is set, a fixing failure might occur.
Display/adj/set range
-7 to 2
-7: -35 deg C, -6: -30 deg C, -5: -25 deg C, -4: -20 deg C, -3: -15 deg
C, -2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
Unit
5 deg C
Default value
0
Supplement/memo
Standby 2: after 5 minutes since the completion of startup/recovery
TMP-ST1L
Adj of standby 1 pressure temperature
Lv.1 Details
To adjust the standby 1 pressure temperature control temperature,
pressure start target temperature.
Display/adj/set range
-1 to 3
-1: -10 deg C, 0: 0 deg C, 1: +10 deg C, 2: +20 deg C, 3: +30 deg C
Unit
10 deg C
Default value
0
TMP-ST2L
Adj of standby 2 pressure temperature
Lv.1 Details
To adjust the standby 2 pressure temperature control temperature.
Display/adj/set range
-1 to 3
-1: -10 deg C, 0: 0 deg C, 1: +10 deg C, 2: +20 deg C, 3: +30 deg C
Unit
10 deg C
Default value
0
TMP-P1-1
Adj of Plain ppr 1 print temperature 1
Lv.2 Details
To adjust the print temperature 1 for "Plain 1."
Set a positive value when a fixing failure occurs, and set a negative
value when a separation failure or wrinkles occur.
When an image failure occurs, adjust appropriately.
Use 0 (initial value) in the normal operation.
Use case
When a fixing failure, a separation failure, wrinkles or an image
failure occurs
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
When -3 or less is set, a fixing failure might occur.
Display/adj/set range
-9 to 2
-9: -45 deg C, -8: -40 deg C, -7: -35 deg C, -6: -30 deg C, -5: -25 deg
C, -4: -20 deg C, -3: -15 deg C, -2: -10 deg C, -1: -5 deg C, 0: 0 deg C,
1: +5 deg C, 2: +10 deg C
Unit
5 deg C
Default value
0
COPIER> OPTION> IMG-FIX
TMP-P1-2
Plain ppr1ini rotn temp, print temp 2&3
Lv.2 Details
To adjust the initial ration temperature and print temperature 2 and 3
for "Plain 1".
Set a positive value when a fixing failure occurs, and set a negative
value when a separation failure or wrinkles occur.
When an image failure occurs, adjust appropriately.
Use 0 (initial value) in the normal operation.
Use case
When a fixing failure, a separation failure, wrinkles or an image
failure occurs
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
When -3 or less is set, a fixing failure might occur.
Display/adj/set range
-7 to 2
-7: -35 deg C, -6: -30 deg C, -5: -25 deg C, -4: -20 deg C, -3: -15 deg
C, -2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
Unit
5 deg C
Default value
0
TMP-P2-1
Adj of plain ppr 2 print temperature 1
Lv.2 Details
To adjust the print temperature 1 for "Plain 2".
Set a positive value when a fixing failure occurs, and set a negative
value when a separation failure or wrinkles occur.
When an image failure occurs, adjust appropriately.
Use 0 (initial value) in the normal operation.
Use case
When a fixing failure, a separation failure, wrinkles or an image
failure occurs
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
When -3 or less is set, a fixing failure might occur.
Display/adj/set range
-9 to 2
-9: -45 deg C, -8: -40 deg C, -7: -35 deg C, -6: -30 deg C, -5: -25 deg
C, -4: -20 deg C, -3: -15 deg C, -2: -10 deg C, -1: -5 deg C, 0: 0 deg C,
1: +5 deg C, 2: +10 deg C
Unit
5 deg C
Default value
0
5