COPIER> OPTION> IMG-DEV
DMX-OF-M
Adjustment of M-color D-max setting
Lv.2 Details
Even auto gradation adjustment is executed, the density on a solid
part (M-color image) might be inappropriate, so use this mode to
adjust the D-max control setting.
When the density is low, increase the value, and when the density is
high, decrease the value.
Use case
When the density on the solid part of the image is inappropriate
although auto gradation adjustment is executed
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
3) Execute the auto gradation adjustment.
Caution
Be sure to execute auto gradation adjustment (full adjustment) after
the setting is done.
Display/adj/set range
-3 to 3
Default value
0
DMX-OF-C
Adjustment of C-color D-max setting
Lv.2 Details
Even auto gradation adjustment is executed, the density on a solid
part (C-color image) might be inappropriate, so use this mode to
adjust the D-max control setting.
When the density is low, increase the value, and when the density is
high, decrease the value.
Use case
When the density on the solid part of the image is inappropriate
although auto gradation adjustment is executed
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
3) Execute the auto gradation adjustment.
Caution
Be sure to execute auto gradation adjustment (full adjustment) after
5
the setting is done.
Display/adj/set range
-3 to 3
Default value
0
DMX-OF-K
Adjustment of Bk-color D-max setting
Lv.2 Details
Even auto gradation adjustment is executed, the density on a solid
part (Bk-color image) might be inappropriate, so use this mode to
adjust the D-max control setting.
When the density is low, increase the value, and when the density is
high, decrease the value.
Use case
When the density on the solid part of the image is inappropriate
although auto gradation adjustment is executed
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
3) Execute the auto gradation adjustment.
Caution
Be sure to execute auto gradation adjustment (full adjustment) after
the setting is done.
Display/adj/set range
-3 to 3
Default value
0
5-350
COPIER> OPTION> IMG-DEV
SLS-TM-Y
Adj Y developer ejectn time:continuous
Lv.2 Details
In case of many continuous jobs, the developer might increase or
decrease too much.
To keep the proper developer amount, adjust the time which Y-color
developer is forcibly ejected.
Use case
When the developer increases or decreases too much at continuous
jobs
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
0 to 10
Default value
0
SLS-TM-M
Adj M developer ejectn time:continuous
Lv.2 Details
In case of many continuous jobs, the developer might increase or
decrease too much.
To keep the proper developer amount, adjust the time which M-color
developer is forcibly ejected.
Use case
When the developer increases or decreases too much at continuous
jobs
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
0 to 10
Default value
0
SLS-TM-C
Adj C developer ejectn time:continuous
Lv.2 Details
In case of many continuous jobs, the developer might increase or
decrease too much.
To keep the proper developer amount, adjust the time which C-color
developer is forcibly ejected.
Use case
When the developer increases or decreases too much at continuous
jobs
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
0 to 10
Default value
0
SLS-TM-K
Adj Bk developer ejectn time:continuous
Lv.2 Details
In case of many continuous jobs, the developer might increase or
decrease too much.
To keep the proper developer amount, adjust the time which Bk-color
developer is forcibly ejected.
Use case
When the developer increases or decreases too much at continuous
jobs
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
0 to 10
Default value
0