Error Code

Error Code Details

■ E000 to E015
E
Detailed
Occurance
Items
code
code
area
E000 -0001
-05
Title
Fixing belt temperature rise is insufficient at power ON.
Description
Fixing main thermistor (THM1-1) temperature does
of detection
not reach 50 degrees Celsius within 120 seconds after
startup of fixing belt temperature control.
Measures
Check if the detection temperature of the thermistor is
risen in service mode (COPIER> DISPLAY> ANALOG>
FIX-xx).
A. In case that either one of the thermistor detection
B. In case that neither of them are not risen
NOTE: After performing the above remedy work, go
through the following to clear the error: COPIER>
FUNCTION> CLEAR> ERR
Description
temperature is risen
A-1. Replace the fixing belt unit
A-2. Faulty drawer connector -> Clean the drawer
connector or replace the fixing drawer cable
B-1. Check the connection of the fixing thermistor
(to see if the connection of the drawer is
faulty, the connector is physically removed or
disconnected) -> replace the fixing belt unit
B-2. Check the connection of the IH power
connector (to see if the connector is physically
removed or disconnected, or the cable is caught)
B-3. Replace the IH power unit
B-4. Replace the DC controller PCB
E
Detailed
Occurance
Items
code
code
area
E000 -0101
-05
Title
Pressure belt temperature rise is insufficient at power
ON.
Description
Pressure main thermistor (THM2) temperature does
of detection
not reach 50 degrees Celsius within 250 seconds after
startup of pressure belt temperature control.
Measures
Check if the detection temperature of the thermistor is
risen in service mode (COPIER> DISPLAY> ANALOG>
FIX-xx).
A. In case that either one of the thermistor detection
B. In case that neither of them are not risen
NOTE: After performing the above remedy work, go
through the following to clear the error: COPIER>
FUNCTION> CLEAR> ERR
E001 -0001
-05
Title
Abnormal temperature rise of fixing main thermistor
(circuit failure)
Description
Fixing main thermistor (THM1-1) sensed an abnormal
of detection
high temperature. (ASIC detection)
Measures
Check the detection temperature of the fixing main
thermistor (THM1-1) in service mode (COPIER>
DISPLAY> ANALOG> FIX-UC).
A. In case that the detection temperature is 250 degC
B. In case that the detection temperature is other than
NOTE: After performing the above remedy work, go
through the following to clear the error: COPIER>
FUNCTION> CLEAR> ERR
Description
temperature is risen
A-1. Check the pressure belt main thermistor
(to see if the thermistor is disconnected, the
harness of the thermistor is disconnected,
foreign substance is in the thermistor, failure of
the thermistor) -> replace the main thermistor or
the pressure stay
A-2. Faulty drawer connector is a possible cause
-> clean the drawer connector or replace the
fixing drawer cable
B-1. Check the connection of the AC driver
connector (to see if the connector is physically
removed or disconnected, or the cable is caught)
B-2. Replace the AC driver unit
B-3. Replace the DC controller PCB
B-4. Replace the pressure belt unit
A-1. The cable of the fixing main thermistor is
caught -> replace the fixing belt unit
250 degC
B-1. Replace the DC controller PCB
3