Canon imageRUNNER ADVANCE 9070 PRO series Service Manual Digest page 414

Hide thumbs Also See for imageRUNNER ADVANCE 9070 PRO series:
Table of Contents

Advertisement

ADJUST
■ ADJ-XY
COPIER> ADJUST> ADJ-XY
ADJ-X
Adj of img pstn in book mode: vert scan
Lv.1 Details
To adjust the image reading start position (image lead edge position)
in vertical scanning direction.
When replacing the Reader Controller PCB/clearing RAM data, enter
the value of service label.
When the non-image width is larger than the standard value, set the
smaller value.
When out of original area is copied, set the larger value.
As the value is incremented by 1, the image position moves to the
trailing edge side by 0.1mm.
Use case
When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
Do not use this at the normal service.
Display/adj/set range
1 to 100
Unit
0.1 mm
Default value
29
ADJ-Y
Adj of img pstn in book mode: horz scan
Lv.1 Details
To adjust the image reading start position in horizontal scanning
direction.
When replacing the Reader Controller PCB/clearing RAM data, enter
the value of service label.
When the non-image width is larger than the standard value, set the
5
smaller value.
When out of original area is copied, set the larger value.
As the value is incremented by 1, the image position moves to the
rear side by 0.1mm.
Use case
When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
After the setting value is changed, write the changed value in the
service label.
Display/adj/set range
36 to 236
Unit
0.1 mm
Default value
116
5-186
COPIER> ADJUST> ADJ-XY
ADJ-Y-DF
Adj img pstn in DADF mode:horz scan[Frt]
Lv.1 Details
To adjust the image reading start position in horizontal scanning
direction at DADF reading.
When replacing the Reader Controller PCB/clearing RAM data, enter
the value of service label.
As the value is incremented by 1, the image position moves to the
rear side by 0.1mm.
Use case
When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
After the setting value is changed, write the changed value in the
service label.
Display/adj/set range
2 to 202
Unit
0.1 mm
Default value
102
STRD-POS
Adj read pstn in DADF mode: front side
Lv.1 Details
To adjust the reading position at DADF reading (front side).
When replacing the Reader Controller PCB/clearing RAM data, enter
the value of service label.
Use case
When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
After the setting value is changed, write the changed value in the
service label.
Display/adj/set range
-100 to 100
Unit
0.1 mm
Default value
0
Related service mode
COPIER> FUNCTION> INSTALL> STRD-POS
ADJ-X-MG
Adj img ratio in book mod:vert scan[frt]
Lv.1 Details
To make a fine adjustment of image magnification in vertical
scanning direction at copyboard reading.
When replacing the Reader Controller PCB/clearing RAM data, enter
the value of service label.
As the value is incremented by 1, the image magnification changes
by 0.01%.
+: Enlarge
-: Reduce
Use case
When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
2) Turn OFF/ON the main power switch.
Caution
After the setting value is changed, write the changed value in the
service label.
Display/adj/set range
-50 to 50
Unit
0.01%
Default value
0

Hide quick links: