COPIER> OPTION> IMG-FIX
TMP-C3
Coat ppr3 ini rotn temp, print temp 1-3
Lv.2 Details
To adjust the initial rotation temperature, print temperature 1 to 3 for
"Coated 3".
Set a positive value when a fixing failure occurs.
In addition, use this mode when an image failure or deterioration of
gloss occurs.
Use 0 (initial value) in the normal operation.
Use case
When a fixing failure, an image failure, or deterioration of gloss
occurs
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
-2 to 2
-2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
Unit
5 deg C
Default value
0
TMP-C4
Coat ppr4 ini rotn temp, print temp 1-3
Lv.2 Details
To adjust the initial rotation temperature, print temperature 1 to 3 for
"Coated 4".
Set a positive value when a fixing failure occurs.
In addition, use this mode when an image failure or deterioration of
gloss occurs.
Use 0 (initial value) in the normal operation.
Use case
When a fixing failure, an image failure, or deterioration of gloss
occurs
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
-2 to 2
-2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
Unit
5 deg C
5
Default value
0
TMP-THIN
Thin ppr ini rotn temp, print temp 1-3
Lv.2 Details
To adjust the initial rotation temperature, print temperature 1 to 3 for
"Thin Paper".
Set a negative value when wrinkles or separation failure occurs, and
set a positive value when a fixing failure occurs.
In addition, use this mode when an image failure or deterioration of
gloss occurs.
Use 0 (initial value) in the normal operation.
Use case
When wrinkles, a separation failure, a fixing failure, an image failure,
or deterioration of gloss occurs
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
-2 to 2
-2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
Unit
5 deg C
Default value
0
5-342
COPIER> OPTION> IMG-FIX
TMP-OHT
Transp ini rotn temp, print temp 1-3
Lv.2 Details
To adjust the initial rotation temperature, print temperature 1 to 3 for
"Transparency".
Set a positive value when a fixing failure occurs.
In addition, use this mode when an image failure or deterioration of
gloss occurs.
Use 0 (initial value) in the normal operation.
Use case
When a fixing failure, an image failure, or deterioration of gloss
occurs
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
-2 to 2
-2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
Unit
5 deg C
Default value
0
TMP-L
Pressure ini rotn temp, print temp 1-3
Lv.2 Details
To adjust the pressure temperature control temperature (initial
rotation temperature, print temperature 1 to 3). (Common setting for
all paper types)
Use 0 (initial value) in the normal operation.
Use case
When a fixing failure or an image failure occurs (Adjust the fixing
control temperature in the normal operation.)
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
-1 to 3
-1: -10 deg C, 0: 0 deg C, 1: +10 deg C, 2: +20 deg C, 3: +30 deg C
Unit
10 deg C
Appropriate target value 0
Default value
0
DWN-TMP
Adj of down sequence temp threshold VL
Lv.2 Details
To adjust the threshold value of the temperature at which the
machine goes into the down sequence.
Use 0 (initial value) in the normal operation.
As the value is smaller, the machine is less likely to enter the down
sequence.
When -4 is set, the down sequence actually becomes OFF.
Use case
When making adjustments according to the environment and media.
Conditions in which the machine is likely to go into the down
sequence (the center temperature is likely to be lowered): 500 sheets
or more of continuous prints in small size, LL or lower temperature
environment, input voltage lower than the rated voltage
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
-4 to 1
-4: -10 deg C, -3: -3 deg C, -2: -2 deg C, -1: -1 deg C, 0: 0 deg C, 1:
+1 deg C
Default value