Canon imageRUNNER ADVANCE 9070 PRO series Service Manual Digest page 66

Hide thumbs Also See for imageRUNNER ADVANCE 9070 PRO series:
Table of Contents

Advertisement

E
Detailed
Occurance
Items
code
code
area
E020 -0390
-05
Title
Description
of detection
Measures
3
3-40
Description
Patch (C) density lower limit error
The ATR patch detection output (SigD) is less than 79.
• When the value of COPIER> DISPLAY> DENS>
P-LED-DA is large (153(D) or more) and the value of
P-SENS-P is small, there is a high possibility that dirt is
applied to the patch sensor.
• This occurs only at a regular timing. When the value
of COPIER> DISPLAY> DENS> DENS-S-x is small
(2 digits), there is a high possibility that breaking
occurred.
1. Check whether the developing assembly and the drum
unit are properly installed.
2. Clean the patch sensor.
3. Check the connection between the patch sensor and
the DC controller interface PCB. (Connector, Shorting)
Sensor side: J7412, J8035 PCB side: J1242
4. Check open/close operation of the patch shutter.
5. Check whether scratches/dirt are applied to the ITB.
If many scratches are found, replace the ITB. If dirt
is applied, clean the ITB. In this case, check the ITB
cleaning blade at the same time.
6. Replace the patch sensor unit.
NOTE:
This error also occurs when there is not enough toner in
the developing assembly. In this case, check the supply-
related parts in the developing assembly.
E
Detailed
Occurance
Items
code
code
area
E020 -0391
-05
Title
Patch (C) density upper limit error
Description
The ATR patch detection output (SigD) is more than 970.
of detection
Measures
• When the value of COPIER> DISPLAY> DENS>
P-LED-DA is large (153(D) or more) and the value of
P-SENS-P is small, there is a high possibility that dirt is
applied to the patch sensor.
• This occurs only at a regular timing. When the value
of COPIER> DISPLAY> DENS> DENS-S-x is small
(2 digits), there is a high possibility that breaking
occurred.
1. Check whether the developing assembly and the drum
unit are properly installed.
2. Clean the patch sensor.
3. Check the connection between the patch sensor and
the DC controller interface PCB. (Connector, Shorting)
Sensor side: J7412, J8035 PCB side: J1242
4. Check open/close operation of the patch shutter.
5. Check whether scratches/dirt are applied to the ITB.
If many scratches are found, replace the ITB. If dirt
is applied, clean the ITB. In this case, check the ITB
cleaning blade at the same time.
6. Replace the patch sensor unit.
NOTE:
This error also occurs when there is not enough toner in
the developing assembly. In this case, check the supply-
related parts in the developing assembly.
E020 -03A0
-05
Title
Toner density sensor (C) output lower limit error
Description
The toner density sensor output (Vsig_ind) is less than
of detection
43.
Measures
1. Check the connection between the toner density sensor
and the DC controller interface PCB. (Connector,
Breaking (shorting))
<Y> sensor side: J7133, J8028, J8087 PCB side:
J1240, J8085
<M> sensor side: J7134, J8029, J8088 PCB side:
J1240, J8085
<C> sensor side: J7135, J8030, J8089 PCB side:
J1240, J8086
<Bk> sensor side: J7146, J8015, J8117 PCB side:
J1240, J8086
2. Check whether disconnection or shorting of the toner
density sensor occurs or not.
3. Replace the developing assembly.
Description

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents