■ ANALOG
COPIER> DISPLAY> ANALOG
TEMP
Display of outside temperature
Lv.1 Details
To display the temperature outside the machine.
This is measured by the Environment Sensor that measures the
outside air.
Use case
When checking the temperature outside the machine
Display/adj/set range
0 to 60
Unit
Deg C
Appropriate target value 20 to 27
Related service mode
COPIER> DISPLAY> ANALOG> HUM, ABS-HUM, PDK-TEMP,
MDK-TEMP
HUM
Display of outside humidity
Lv.1 Details
To display the humidity outside the machine.
This is measured by the Environment Sensor that measures the
outside air.
Use case
When checking the humidity outside the machine
Display/adj/set range
0 to 100
Unit
%
Appropriate target value 30 to 70
Related service mode
COPIER> DISPLAY> ANALOG> TEMP, ABS-HUM, PDK-HUM,
MDK-HUM
ABS-HUM
Display of outside moisture amount
Lv.1 Details
To display the absolute moisture amount outside the machine.
This is measured by the Environment Sensor that measures the
outside air.
Use case
When checking the moisture amount outside the machine
5
Display/adj/set range
0 to 100
Unit
g (g/m3)
Appropriate target value 0 to 22
Related service mode
COPIER> DISPLAY> ANALOG> TEMP, HUM
DR-TEMP
[Not Used]
FIX-UC
Dis of Fixing Belt center temperature
Lv.1 Details
To display the center temperature of the Fixing Belt detected by the
Fixing Main Thermistor.
Use case
When checking the temperature at the center of Fixing Belt
Display/adj/set range
0 to 999
Unit
Deg C
FIX-UE
Dis of Fixing Belt rear edge temperature
Lv.1 Details
To display the rear edge temperature of the Fixing Belt detected by
the Fixing Sub Thermistor 1.
Use case
When checking the edge temperature of the Fixing Belt
Display/adj/set range
0 to 999
Unit
Deg C
5-60
COPIER> DISPLAY> ANALOG
FIX-LC
Dis of Pressure Belt center temperature
Lv.1 Details
To display the center temperature of the Pressure Belt detected by
the Pressure Main Thermistor.
Use case
When checking the temperature at the center of the Pressure Belt
Unit
Deg C
Appropriate target value At standby: 90 to 140
At print: 70 to 150 (differs depending on modes)
FIX-LE
Dis of Pressure Belt rear edge temp
Lv.1 Details
To display the rear edge temperature of the Pressure Belt detected
by the Pressure Sub Thermistor 1.
Use case
When checking the edge temperature of the Pressure Belt
Unit
Deg C
Appropriate target value At standby: 70 to 190
At print: 70 to 190 (differs depending on modes)
FIX-LE2
Dis of Pressure Belt front edge temp
Lv.1 Details
To display the front edge temperature of the Pressure Belt detected
by the Pressure Sub Thermistor 2.
Use case
When checking the edge temperature of the Pressure Belt
Display/adj/set range
0 to 999
Unit
Deg C
Appropriate target value At standby: 70 to 190
At print: 70 to 190 (differs depending on modes)
FIX-UE2
Dis of Fixing Belt front edge temp
Lv.1 Details
To display the front edge temperature of the Fixing Belt detected by
the Fixing Sub Thermistor 2.
Use case
When checking the edge temperature of the Fixing Belt
Display/adj/set range
0 to 999
Unit
Deg C
DR-TEMPL
[Not Used]
DEVHUM1
Dis of Y/M color Dev Ass'y humidity
Lv.2 Details
To display the humidity of the Y and M Developing Assembly
detected by the Developing Assembly Inner Temperature Detection
PCB (Y/M).
Use case
When a failure occurs on the developing contrast
Display/adj/set range
0 to 100
Unit
%
Appropriate target value 5 to 80
Related service mode
COPIER> DISPLAY> ANALOG> DEVHUM2, DEVTEMP1,
DEVTEMP2

Hide quick links: