Ricoh D146 Service Manual page 549

Hide thumbs Also See for D146:
Table of Contents

Advertisement

SC No.
Level
SC555-00
D
SC No.
Level
SC557-00
C
SM
Error Name/Error Condition/Major Cause/Solution
Fusing Edge Heater Continuously Heat
After waiting for full power for more than (t6) seconds
continuously, not detected for (t8) seconds.
§
Definition of heater full power
Continuously heating rate set point (maximum heating rate)
§
Measurement start point
After reload (after heater extinguished, after rotation
complete) below the standby temperature (target
temperature), measurement starts after a heater heat-up
request is issued.
§
Measurement stop condition
Rotation started due to a print signal during measurement or
other
§
Maximum heat-up Duty (SP interlinked value) 0% is
excluded
§
Thermistor deformation/float
§
Heater disconnection
§
After excess temperature rise prevention unit operation
§
Replace the thermistor
§
Replace the fusing lamp
§
Replace the fusing unit
Error Name/Error Condition/Major Cause/Solution
Zero Cross Frequency Exceeded
In the event of an error
Frequency instability of commercial power line/Noise
-
5-75
Service Call 501-584
D146/D147/D148/D149/D150